Datasheet

16
Note: It is not possible to mount this product
such that the pressure port faces upward.
Pressure port
faces downward
Pressure port
faces leftward
Pressure port
faces rightward
Pressure port
faces upward
Sensor mounting bracket
MS-DP1-1 (Optional)
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for MS-DP1-1
and MS-DP1-5
PRECAUTIONS FOR PROPER USE
Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
The DP-100L series is designed for use with
non-corrosive gas. It cannot be used with
liquid or corrosive gas.
Wiring
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this sensor,
connect the frame ground (F.G.) terminal of the equipment
to an actual ground.
Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
Incorrect wiring will cause problems with operation.
Connection
Connector
attached cable
[CN-14A(-R)-C
□]
Do not apply stress directly
to the connection cable
leader or to the connector.
Mounting
MS-DP1-1 / MS-DP1-5 sensor mounting brackets are
available separately, and it should be used for mounting.
When tightening the sensor to the sensor mounting
bracket, use a tightening torque of 0.5 N·m or less.
The MS-DP1-2 panel mounting bracket (optional) and the
MS-DP1-3 front protection cover (optional) are also
available.
Front protection cover
MS-DP1-3
Panel mounting
bracket
MS-DP1-2
The MS-DP1-4 panel mounting bracket is available when
switching from the DP2 / DP3 series.
DP-100L
Panel mounting bracket MS-DP1-4
DP2-20
–101.3kPa
OUT2
OUT1
MODE
0-ADJ
DP2 / DP3
Insert
Remove
Remove
Mounting holes
for DP2 / DP3
series
can be used as is.
Front protective cover
DPX-04 (optional)
can be installed on
MS-DP1-4.
The MS-DP1-7 conversion bushing is available. It can be
used to switch between this model and the DP2 / DP3
series. When connecting to the pressure port, use a
tightening torque of 1.0 N·m or less.
Conversion bushing MS-DP1-7
M5 female thread Rc
1
/
8
female thread
The MS-DP1-F□ at attachment is available. If using the
MS-DP1-F□ at attachment (optional), install by following
the procedures given below.
(1) Decide the direction of this product to mount with the
sensor.
(2)
Mount this product with the M3 female threads of the
sensor by using the attached M3 (length 8 mm 0.315 in)
screws. The tightening torque should be 0.5 N·m or less.
M3 (length 8 mm 0.315 in
)
screw (Accessory)
M3 female thread
M3 female thread
(3) Mount this product with the mounting surface by using
the attached M4 (length 20 mm 0.787 in) screws. The
tightening torque should be 1.2 N·m or less.
M4 (length 20 mm 0.787 in)
screw (Accessory)
Groove
Connector attached cable
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
Dual Display Digital Pressure Sensor DP-100L SERIES
DP-100L
SERIES
This catalog is a guide to select a suitable product. Be
sure to read instruction manual attached to the product
prior to its use.