Datasheet

17
30
1.181
30
1.181
20
0.787
1.5
0.059
4.5
0.177
ø8.3
ø0.327
30
1.181
20
0.787
25.5
1.004
M5 female thread,
4 0.157 deep
M3 female thread,
4 0.157 deep
Connector
PRECAUTIONS FOR PROPER USE
Flat attachment MS-DP1-F□
Make sure to mount MS-DP1-F□ with the sensor properly.
If it is not mounted properly, air leakage may occur.
Take care that the excessive mounting and dismounting
of this product may cause deterioration of the O-ring.
If you touch the O-ring of MS-DP1-F□, or any scratch or
dust, etc. is attached to it, air leakage may occur and the
sensing performance may deteriorate.
Take sufcient care when using and storing MS-DP1-F□.
If connecting a commercially-available joint to the
pressure port of the sensor, hold the main unit in your
hand to steady it, and tighten to a torque of 1 N·m or less.
If it is tightened to an excessive torque, the joint or the
main unit may become damaged.
If connecting a commercially-available joint to the
pressure port of the MS-DP1-7 conversion bushing,
tighten to a torque of 9.8 N·m or less.
Piping
14 mm 0.551 in spanner
The tightening torque should be 1 N·m or less when
connecting a coupling to the pressure port of MS-DP1-FM
at attachment.
Coupling (Purchase separately.)
Pressure port
When connecting the coupling to the pressure port of
MS-DP1-FR/FE/FN at attachment, hold the pressure
port with a 14 mm 0.551 in spanner and make sure that
the tightening torque is 9.8 N·m or less.
In addition, in order to prevent any leakage, wind a
sealing tape on the coupling when connecting.
14 mm 0.551 in spanner
Note: Do not tighten the pressure port by holding the product with the spanner.
It may cause the product breakage.
Others
This product has been developed / produced for industrial
use only.
Use within the rated pressure range.
Do not apply pressure exceeding the pressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
Do not use during the initial transient time (0.5 sec.
approx.) after the power supply is switched on.
Avoid dust, dirt, and steam.
Take care that the sensor does not come in direct contact
with water, oil, grease, or organic solvents, such as,
thinner, etc.
Do not insert wires, etc., into the pressure port. The
diaphragm will get damaged and correct operation shall
not be maintained.
Do not operate the keys with pointed or sharp objects.
DP-10□ZL3-M-P(-C)
Sensor
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
Dual Display Digital Pressure Sensor DP-100L SERIES
DP-100L
SERIES