Datasheet

9
SPECIFICATIONS
Type Discrete wire type M12 connector type
Item Model No. FX-551L3-P-C2 FX-551L3-P-J
Regulatory compliance EMC Directive, RoHS Directive
Supply voltage 12 to 24 V DC
+10
−15
% Ripple P-P 10 % or less
Power consumption
Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 720 mW or less (current consumption 30 mA or less at 24 V supply voltage)
Communication
output (C/Q)
(Note 2)
IO-Link
communication
IO-Link Specication V1.1
Baud rate COM3 (230.4 kbps)
Process data 4 byte
Minimum
cycle time
1.0 ms
Control output (DO)
PNP open-collector transistor
Maximum source current: 50 mA
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 2 V or less (Note 3) (at maximum source current)
Output operation Switchable either Light-ON or Dark-ON by L/D mode
Short-circuit protection
Incorporated
Response time STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Incident light sensitivity setting Incorporated, 4 steps
Incident light intensity display
range
STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Timer function Incorporated with variable OFF-delay / ON-delay / One-shot, switchable either effective or ineffective
Timer period 0.1 to 999.9 ms approx., in units of 0.1 ms approx.
Different frequency
interference prevention
function (Note 4)
Incorporated (up to 4 units). Note that the response time varies depending on the setting.
F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less
Protection IP40 (IEC)
Ambient temperature
-10 to +55 °C +14 to +131 °F (If 4 to 7 units are mounted in cascade: -10 to +50 °C +14 to +122 °F or if 8 to 16 units
are mounted in cascade: -10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed),
Storage: -20 to +70 °C -4 to +158 °F
Emitting element (modulated) Red LED (Peak emission wavelength: 660 nm 0.026 mil)
Material Enclosure, Case cover: Polycarbonate, Switch: Polyacetal
Cable 0.2 mm
2
4-core cabtyre cable, 2 m 6.562 ft long
0.2 mm
2
cabtyre cable with M12 connector, 0.3 m 0.984 ft long
Cable extension
Extension up to total 20 m 65.617 ft is possible with 0.3 mm
2
, or more, cable.
(Condition of CE compliance: less tan 20 m 65.617 ft) (however, supply voltage 12 V DC or more)
Weight
Net weight: 55 g approx., Gross weight: 80 g approx. Net weight: 35 g approx., Gross weight: 60 g approx.
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
3) In case of using the cable (cable length 2 m 6.562 ft).
4) This function increases the hysteresis. Check the sensing condition when using the function.
Digital Fiber Sensor FX-550L SERIES
FX-550L
SERIES