User Manual
High−level Instructions
3 − 746
When Lower limit S1+1 and S1 Input value S3+1 and S3 Upper limit S2+1 and S2, the input value S3+1
and S3 stored in D+1 and D as the output value.
Output value D+1 and D
[S2+1, S2]
[S1+1, S1]
Input value S3+1 and S3
Lower limit S1+1 and S1
Upper limit S2+1 and S2
Specifying the integer device with [S1], [S2] and [S3], the integer data is internally converted to real numbers
before operations continue.
F347 FLIMT, % DT10, % DT20, DT30, DT40
R0
Specifying the integer device with [D], the real numbers are automatically converted into integer data.
F347 FLIMT, DT10, DT20, DT30, % DT40
R0
When the constant K is specified in S1, S2 and S3, the operations are the same as when a integer device is
specified.
Flag conditions
・Error flag (R9007): Turns on and stays on when:
・Error flag (R9008): Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− If data other than real number data is specified in (S1+1 and S1), (S2+1
and S2) and (S3+1 and S3).
− (S1+1, S1) > (S2+1, S2).
− If result of operating is outside integer range when integer device is
specified in D+1 and D.
・= flag (R900B): Turns on when result of operating is within the range of the upper and lower
limits.