FEATURES GUIDE

General Features
174 Features Guide
Line Access, Automatic
Description
Allows the extension user to dial the automatic line access number and access an idle line from
the CO line groups assigned for the extension. The digital proprietary telephone user can use
the Loop-CO button in place of the access number.
Conditions
Each extension is subject to System Programming items for CO lines available to access.
An idle CO line is selected from the CO line groups assigned to the station. If 1 CO line
group is available, an idle line is selected from that group. If multiple CO line groups are
available, the CO line group hunting sequence is determined by System Programming.
This feature requires a CO button (L-CO or S-CO) assignment on a digital proprietary
telephone (DPT). Dialling the line access code selects a CO button on a DPT according to
the priority:
S-CO > L-CO on a hunted CO line group
If Idle Line Preference Outgoing is set on the telephone, the user can access an idle line
only by going off-hook.
The system waits for a programmed time before dialling after a CO line is seized.
Programming Guide References
[100] Flexible Numbering
[103] Automatic Access CO Port Assignment
[400] CO Port Connection Assignment
[605-606] Outgoing Permitted CO Line Assignment Day/Night
Features Guide References
CO Line Connection Assignment Outgoing
User Manual References
2.2.1 Basic Calling