User manual

Operation - Using the Sprayer (continued)
28
0154 2
Priming valve
Pressure adjustment knob
7. Adjust pressure
and agitation as
needed
-Rotate the pressure adjustment knob until the sprayer is running at the
desired pressure.
-O pen priming valve to circulate flow back to the tank and create agi tation.
Open until desired amount of agitation is achieved.
8. Leaving
unattended
If the sprayer must be left unattende d at any time:
a) Disconnect power to the sprayer.
b) Relieve system pressure by depressing the gun trigger.
c) Turn off the vehicle. Set brake or block the wheels.
9. Discontinue use if
clogged or
inoperative
If the sprayer be comes clogged or inoperative during use, discontinue use
immediately.
- DO NOT attempt to service while chemicals are in the sprayer and power is
connected.
- Return to service area to review instructions for troubleshooting before
attempting to service.
Note: A reserve, clean container capable of holding at least 16 gallons should be kept for use when the sprayer
tank needs to be emptied temporarily for repairs. It is advisable to purchase a reserve tank suitable for
pesticide storage from Northern Tool and Equipment for use in these circumstances. The container
should be properly labeled as to its contents if it is used.