Instruction Manual

ENGLISH
5
SETTING UP THE SPECIAL FUNCTIONS
SETTING UP THE SPECIAL FUNCTIONS
After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.
The control panel can be used for multiple installations. Some functions may not be applicable to your unit.
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
MON TUE WEDTHU FRI SAT SUN
REMOTE
ON
Day display
YES / NO / Temperature display
SETTING / STATUS indicatorFunctions*Timer display
SET
SELECT
CANCEL
SETTING
STATUS
SEARCH
CHECK
SELECT FUNCTIONS AND SET YOUR DESIRED TIMER
1. Press
SET
and
CHECK
simultaneously for 5 seconds to enter special setting mode. “SETTING” and “STATUS” indicator is ON.
2. Press
or to browse functions.
3. Press
SELECT
to enter the function.
4. Press
or to enable YES or disable NO function, or set your desired day and time.
5. Press
SET
to con rm.
Display Function *
External Thermo Controller (YES / NO)
To set external thermo controller connection.
Tank Connection (YES / NO)
To set tank connection.
Heating Priority (YES / NO)
To choose the heat pump only use for Heating side during HEAT + TANK mode.
Heating Heat-up Interval Set
To set timer for Heating during HEAT + TANK mode (0.5hour ~ 10hours).
Tank Heat-up Interval Set
To set timer for Tank during HEAT + TANK mode (5minutes ~ 1hour 35minutes).
Booster Heater Delay Time Set
To set delay timer for booster heater to ON if tank temperature is not reached (20minutes ~ 1hour 35minutes).
Sterilization (YES / NO)
To set sterilization, if required.
Sterilization Day & Time Set
To set timer for sterilization (only once a week).
Sterilization Temperature Set
To set temperature for sterilization function (40°C ~ 75°C).
Sterilization Continue Time
To set timer to maintain heating temperature in order to complete the sterilization function (5minutes ~ 1hour).
01_F567343_OYTH0912-00_EN.indd 501_F567343_OYTH0912-00_EN.indd 5 1/28/2010 9:51:01 AM1/28/2010 9:51:01 AM