Installation Instructions Outdoor Dome Housings PODV7CWNS/PODV7CPNS Manufactured By: for ® Before attempting to connect or operate this product, please read these instructions completely.
IMPORTANT SAFEGUARDS 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should be retained for future reference. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to. 4. Follow Instructions - All operating and user instructions should be followed. 5. Electrical Connections - Only a qualified electrician should make electrical connections. 6.
PODV7CWNS/PODV7CPNS IP Ready Network Housing ASSEMBLING THE UNIT: 1. Remove content from all boxes. Contents should include: IP Ready Network Housing with 24Vac input, wall mount or pendant mounting, heater & blowers, WV-NS202 and camera.
INSTALLATION of the WV-NV202 Camera in the PODV7 Housing 1. Install the quick release plate on top of the spacers already installed in the housing. Note the orientation of the bracket. The securing tab must be facing the front of the housing. Secure the quick release plate into the housing using the (4) #8 bolts and star washers provided in the packet assembly. 2. Attach the Camera to the quick release plate. Attach safety lanyard to the back of the camera.
WIRING INSTRUCTIONS (OUTSIDE OF HOUSING) If you wish to provide a single power transformer it is recommended that: 1. Be certain that you know the total power consumption of the housing Heater (25 watts) + Blower (1 watt) + camera pan/tilt (25 watts). RJ45 2. Check the supplied wiring chart (see below) to be sure that you have the proper gauge wire for the distance that you intend to run your power wires. BNC (Large) Power 3.
INSTALLING THE HOUSING ASSEMBLY: ! Be sure the bracket is properly and securely mounted to a supporting structure capable of rigidly holding the weight of the entire unit. NOTE: This unit is designed for operation in an upright position. Installing the housing upside down may cause damage to the internal equipment, and will void the warranty. INSTALLING PENDANT MOUNT 1. This unit includes a 1½" NPT housing for a standard 1½" NPT pipe.
INSTALLING WALL MOUNT CONNECTING THE TRIM RING ASSEMBLY TO THE HOUSING TOP: A wall mount bracket comes standard with this unit, and a template is included to use as a guide for mounting the bracKet to a wall. 1. Open the access door on the bottom of the wall mount by loosening the screw nearest the mounting plate. 1. Choose the desired location for installation and mark the drill holes using the template. Screw (2) bolts (not provided) about ¾ of the way into the (2) top holes.
Exploded View for Replacement Parts 17 16 11 10 18 (1) 9 (1) (2) 6 8 5 7 19 (1) 15 (3) 12 14 13 4 3 2 1 - -
Replacement Parts List Part Number Description 1 RPRH702 Lower Trim Ring (White) 2 RC7C Clear Replacement Capsule RC7T Tinted Replacement Capsule 3 RPRH726 Spacing Ring 4 RPRH703 Clamping Ring 5 RPFD072 24VAC Heater 6 RPRH707 Connection PCB 7 RPFD060 Camera Bracket 8 RPFD040 Upper Bracket Assembly 9 RPRH709 Housing Top 10 RPFD2612 Housing Top Gasket 11 WM10 Wall Mount Bracket (Black) 12 RPFD080 12VDC Blower (Used on 24VAC Units) 13 RPNET02 24 to 12DC Power Supply
Mounting Template R .733 2.132 5.500 1.537 2.981 2.000 3.