Operation Manual
Table Of Contents
- Wichtige Hinweise zur Sicherheit
- Kapitel 1 Vorbereitung
- Kapitel 2 Erste Schritte
- Kapitel 3 Grundlagen der Bedienung
- Kapitel 4 Einstellungen
- Menünavigation
- Menü [BILD]
- Menü [POSITION]
- Menü [ERWEITERTES MENÜ]
- Menü [MENUE SPRACHE(LANGUAGE)]
- Menü [ANZEIGE OPTION]
- Menü [PROJEKTOR EINSTELLUNGEN]
- [PROJEKTOR ID]
- [PROJEKTIONSARTEN]
- [KÜHLUNG]
- [HÖHENLAGE MODUS]
- [LAMPENWAHL]
- [LAMPENWECHSEL]
- [LAMPEN LEISTUNG]
- [BEREITSCHAFTS MODUS]
- [PLANUNG]
- [EINST. STARTVORGANG]
- [RS-232C]
- [REMOTE2 MODUS]
- [STATUS]
- [AUTO-ABSCHALTUNG]
- [FUNKTIONSTASTEN MENÜ]
- [DATUM UND UHRZEIT]
- [ALLE BENUTZERDATEN SICHERN]
- [ALLE BENUTZERDATEN LADEN]
- [INITIALISIEREN]
- [SERVICE PASSWORT]
- Menü [TESTBILDER]
- Menü [LISTE DER REGISTRIERTEN SIGNALE]
- Menü [SICHERHEIT]
- Menü [NETZWERK]
- Kapitel 5 Wartung
- Kapitel 6 Anhang
DEUTSCH - 109
Kapitel 4 Einstellungen — Menü [NETZWERK]
Inhalt der versendeten Mail
Beispiel der versendeten E-Mail, wenn E-Mail eingestellt ist
Die folgende E-Mail wird versendet , wenn die E-Mail-Einstellungen eingerichtet wurden.
=== Panasonic projector report(CONFIGURE) ===
Projector Type : DW740
Serial No : SH1234567
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 60] minutes interval
INTAKE AIR TEMPERATURE Over [ 45C / 113F ]
ERROR [ OFF ]
LAMP1 RUNTIME [ OFF ] at REMAIN [ 400] H
LAMP1 RUNTIME [ OFF ] at REMAIN [ 200] H
LAMP2 RUNTIME [ OFF ] at REMAIN [ 400] H
LAMP2 RUNTIME [ OFF ] at REMAIN [ 200] H
INTAKE AIR TEMPERATURE [ OFF ]
PERIODIC REPORT
Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ]
Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ]
00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ]
04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ]
08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ]
12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ]
16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ]
20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ]
----- check system -----
MAIN CPU BUS [ OK ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP1 REMAIN TIME [ OK ]
LAMP2 REMAIN TIME [ OK ]
LAMP1 STATUS [ OK ]
LAMP2 STATUS [ OK ]
SHUTTER [ OK ]
INTAKE AIR TEMP.SENSOR [ OK ]
OPTICS MODULE TEMP.SENSOR [ OK ]
AROUND LAMP TEMP.SENSOR [ OK ]
BATTERY [ OK ]
COLOR WHEEL [ OK ]
COVER OPEN [ OK ]
FILTER UNIT [ OK ]
AIR FILTER [ OK ]
(Error code 00 00 00 00 00 00 00 00)
Intake air temperature : 26 degC / 78 degF
Optics module temperature : 39 degC / 102 degF
Around lamp temperature : 30 degC / 86 degF
PROJECTOR RUNTIME 1 H
POWER ON 1 times
LAMP1 ON 1 times
LAMP1 ECO 0 H
LAMP1 NORMAL 0 H
LAMP1 REMAIN 1999 H
LAMP2 ON 1 times
LAMP2 ECO 0 H
LAMP2 NORMAL 1 H
LAMP2 REMAIN 1999 H
-------- Current status ---------
MAIN VERSION 1.00
NETWORK VERSION 1.00
SUB VERSION 1.00
LAMP STATUS LAMP1=ON LAMP2=ON
INPUT SIGNAL RGB1 ---
0.00kHz / 0.00Hz
REMOTE2 STATUS DISABLE
----- Wired Network configuration -----
DHCP Client OFF
IP address 192.168.10.100
MAC address 70:58:12:00:00:00
Wed Jan 18 11:42:37 2012
----- Memo -----