Operating Instructions

14
TQBM0479
The main unit can be wall mounted using the supplied wall mount brackets, etc. Make sure that the
screw used and the wall are strong enough to support the weight of at least 60 kg.
The screws and other items are not supplied as the type and size will vary with each installation.
Refer to step 3 for details about the required screws.
Be sure to attach the fall prevention cord as a secondary safety measure.
Supplied accessories
Additionally required accessories (commercially available)
Screws for wall mounting............................................................................................................. k 2
Fall prevention cord (diameter: 1.5 mm to 2.0 mm)..................................................................... k 2
Screw eyes (to attach the fall prevention cord) ........................................................................... k 2
Use a cord that is capable of supporting over 60 kg.
Lay the unit on a blanket or soft cloth for assembly.
1 Attach the cord to the main unit.
Perform steps 1 in “When placing the main unit in a rack or on a table”. (> 13)
2 Attach the wall mount brackets to the main unit.
When attaching the main unit to a wall
2 Screws 2Wall mount
brackets
A Wall mount bracket (supplied)
B Screw (supplied)
(Rear)
SC-HTB900-EGEBGN-TQBM0479_eng.book 14 ージ 019年10月15日 火曜日 午後3時12