3.3 Specifications
Whole system capacity
R Lobby station (VL-VM series):
Star wiring: up to 1
Bus wiring: up to 6
R Main monitor
*1
(VL-MV10, VL-MWD501,
VL-MVN511,
VL-MWD272, VL-MWD273, VL-MV71,
VL-MV72): up to 32
*2
R Distributor (VL-VM701): up to 8
*3
R Extension box (VL-V703): up to 1
*4
Lobby station (VL-VM series; sold separately)
Power source Power supply unit
VL-PS240: 24 V DC, 0.6 A
or
VL-PS2410: 24 V DC, 2.5 A
Power
consumption
VL-VM101
Standby: 1.8 W
Operating: 9.9 W
Measurement conditions:
–
Lobby station consists of
VL-VM101 (1 pcs.) and
VL-VM301 (1 pcs.).
– VL-MV10 (1 pcs.) is
connected to the lobby
station.
– VL-PS240 is used as the
power supply unit.
Dimensions
(mm) (height ´
width ´
depth)
*10
(excluding
protruding
sections)
Flush mount (small type):
approx. 226 ´ 130 ´ 9
*5
,
*6
Flush mount (large type):
approx. 315 ´ 130 ´ 9
*5
,
*7
Surface mount (small type):
approx. 233 ´ 135 ´ 89
*8
Surface mount (large type):
approx. 322 ´ 135 ´ 89
*9
Mass (weight)
*10
Flush mount (small type):
approx. under 1.3 kg
*6
Flush mount
(large type):
approx. under 1.8 kg
*7
Surface mount (small type):
approx. under 1.7 kg
*8
Surface mount (large type):
approx. under 2.2 kg
*9
Operating
environment
Ambient temperature: approx.
-15 °C to +55 °C
Relative humidity
(non-condensing): up to 90
%
Installation
method
Flush mount (using the back
box; sold separately)
Surface mount (using the back
box and surface mount cover;
sold separately)
External
material
Stainless steel (surface mount
cover)
Aluminum (partially PC and
ABS)
Talking method Hands-free
Image sensor 1/4 inch CMOS sensor (approx.
1M pixels)
Viewing angle Horizontally: approx. 170°
Vertically: approx. 110
°
Minimum
illuminance
required
1 lx (within approx. 50 cm from
the camera lens)
Lighting method White coloured LED lights
IP rating
IP55
*11
,
*12
IK rating
Compliant with IK08
*12
Audio guidance
languages
(when
unlocking
a door)
English/German/French/Italian/
Spanish/Dutch/Arabic/Persian
HAC (Hearing
Aid
Compatibility)
Not Compatible
*1 The available products differ depending on your
region. For more information, please consult your
dealer.
*2 Depending
on the composition of the lobby station's
modules.
*3 Required when using bus wiring.
*4 Required when expanding the lobby stations with
bus wiring.
*5 Excluding sections embedded into the wall.
*6 Includes (VL-VM101 x 1 pcs.) + (VL-VM304 x 2 pcs.)
+ VL-VM602 (small type)
*7 Includes (VL-VM101 x 1 pcs.) + (VL-VM304 x 4 pcs.)
+ VL-VM603 (large type)
*8 Includes (VL-VM101 x 1 pcs.) + (VL-VM304 x 2 pcs.)
+ VL-VM602 + VL-VM502 (small type)
*9 Includes (VL-VM101 x 1 pcs.) + (VL-VM304 x 4 pcs.)
+ VL-VM603 + VL-VM503 (large type)
*10 For France: Does not include the dimensions and
weight of the VIGIK.
*11 Water resistance is only assured if the product is
installed correctly according to the instructions, and
appropriate water protection measures are taken.
*12 When a VIGIK module is installed, the rating does
not include the VIGIK module.
18
3. Preparation