Operating Instructions

wire should be connected to, and insert the DC
wires as shown.
CAUTION
R Insert the power cables firmly all the way into the
terminals. If the cables are not inserted all the
way, heat may be generated.
4 Tighten
the terminal screws to secure the AC and DC
wires (bare wire area) to the terminals, and then use
the cable binders to secure the AC and DC wires
(jacketed area) to the cable binder holes on the top
and bottom on the power supply unit.
A
B
B
D
C
A Terminal screws
B Cable binders connected to cable binder holes
C To lobby station
D To AC power outlet
R Recommended torque:
AC IN terminals: 0.5 N·m {5.1 kgf·cm}
DC IN terminals: 0.45 N·m {4.6 kgf·cm}
5 Strip the remaining ends of the DC wires as shown.
25 mm
7 mm
A
A To DC terminals of power supply unit
6 Solder the ends of the DC wires to the DC plug. Use
insulation sleeves to insulate the wires.
DC+
DC
-
DC+
DC
-
BA
C
C
A DC plug
B DC wires
C Insulation sleeve
7 Replace the cable covers and then securely fasten
the cable cover screws.