Operating Instructions

4.3.1 Installation position of the lobby station
and camera range
Refer to the following examples and confirm the area
viewable by
the camera. In each illustration, the viewable
area is indicated by "A" and the centre of the camera
lens is indicated by "B".
Installed on vertical wall, side view
Camera height: 1480 mm
Camera lens angle: 0°
1480 mm
1850 mm
A
72°
730 mm
1120 mm
500 mm
B
Camera height: 1130 mm
Camera lens angle: +15°
1750 mm
1130 mm
810 mm
500 mm
940 mm
72°
A
B
Installed on slanted surface, side view
Camera height: 1020 mm
Surface angle: 60°
Camera lens angle: 0°
500 mm
1020 mm
60°
1320 mm
2280 mm
960 mm
72°
A
B
Camera height: 1000 mm
Surface angle: 45°
Camera lens angle: -15°
2320 mm
500 mm
1000 mm
45°
1380 mm
940 mm
72°
A
B
Top view
500 mm
120°
1730 mm
A
Note:
R The measurements and angles shown here are for
reference purposes and may vary depending on the
environment.
R The angle
of the camera lens can be adjusted ± 15°.
See 4.3.4 Adjusting the camera lens angle
(Page 20).
R Install the lobby station so that the lobby station is not
exposed to strong light. If strong light shines on the
lobby station, the visitor’s face may not be
distinguishable.
16
4. Installation