Operating Instructions

4.3.3 Connecting the wires and cables
1 Connect the LAN cable to the LAN connector.
2 Connect the DC plug to the DC IN connector.
R See 4.2 Installing the power supply unit
(Page 13) for information about installing the
power supply unit.
3 Strip the wires from the electric lock, access
controller, and open door sensor as shown below.
7 mm
4 Insert the wires from the electric lock into the 3-pin
terminal block,
tighten the terminal block screws, and
then attach the 3-pin terminal block to the K-OUT
connection terminals.
R Connect the wires according to the specifications
of the electric lock. Only 2 wire connections are
needed.
S1 and S2: For normally-open circuit type electric
locks
S2 and S3: For normally-closed circuit type
electric locks
R Make sure the wires are inserted fully into the
terminal block and that the terminal block screws
are tight enough to prevent the wires from pulling
out.
R Make sure the 3-pin terminal block snaps into
place and is securely connected to the K-OUT
connection terminals.
5 Insert the wires from the access controller and open
door sensor into the 4-pin terminal block, tighten the
terminal block screws, and then attach the terminal
block to the K-IN connection terminals.
R Connect the wires as follows.
C1 and C2: Access controller
C3 and C4: Open door sensor
R Make sure the wires are inserted fully into the
terminal block and that the terminal block screws
are tight enough to prevent the wires from pulling
out.
R Make sure the 4-pin terminal block snaps into
place and is securely connected to the K-IN
connection terminals.
A B C D
F
G
E
A Wires from electric lock
B DC plug from power supply unit
C Wires from access controller
D Wires from open door sensor
E LAN cable
F 3-pin terminal block
G 4-pin terminal block
Note:
R Refer to 4.4 Wiring schematic (Page 21) for
connection diagrams.
R Refer to 4.5 Wire and cable specifications
(Page 22) for information on the type and length of
wires that can be used.
19