Operating Instructions

7
English
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
User
Control panel preparation
1
Press
.
2
Press
or to set the current day.
3
Press
to confirm.
4
Repeat steps
2
and
3
to set the current time.
Note:
The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
6
Backup Heater For Tank
To activate backup heater during tank operation.
YES YES NO
Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and regulations.
7
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 8 to 10 are skipped.
YES YES NO
8
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~
Sunday
0:00 ~ 23:50
9
Sterilisation Temperature
To set the temperature of sterilisation.
65 °C 40 °C ~ 65 °C
10
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
10 minutes
5 minutes ~
1 hour
11
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 12 is skipped.
NO YES NO
12
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
AAB
13
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from HEAT to COOL.
15 °C 5 °C ~ 25 °C
14
*
1,
*
2
Heat Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from COOL to HEAT.
10 °C 5 °C ~ 25 °C
15
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than
during construction (Refer to Information page).
- 1 day ~ 99 days
To adjust initial settings