System temperature setting
Temperature setting Display
The system controls the temperature for each menu based on the
outdoor ambient temperature.
• To set or change the temperatures, make sure to contact your
nearest authorised dealer.
1
Press and hold for 5 seconds to enter the
temperature range setting mode.
(The display shows SETTING.)
2
Press
or to select a menu.
3
Press to enter the menu.
4
Press or to set the desired temperature.
5
Press
to confirm the setting.
• Repeat steps
2
to
5
to set other menus.
User
Checking the temperature range
1
Press and hold for 5 seconds to enter the temperature range setting mode.
2
Press
or to select a menu.
• Press
to exit.
Menu
Default
setting
Temperature
setting
Display
Setting of low outdoor ambient temperature. -5 °C -15 °C ~ 15 °C
HEAT
Setting of high outdoor ambient temperature. 15 °C -15 °C ~ 15 °C
Setting of water outlet temperature at low outdoor
ambient temperature.
55 °C 25 °C ~ 55 °C
Setting of water outlet temperature at high outdoor
ambient temperature.
35 °C 25 °C ~ 55 °C
During HEAT mode, the water
outlet temperature is adjusted as
is shown the diagram on the right.
It is performed within the preset
temperature range.
<Water outlet
temperature>
<Outdoor ambient temperature>
max. water temp.
min. water temp.
Setting of outdoor ambient temperature to turn
OFF heating operation during HEAT mode.
24 °C 5 °C ~ 35 °C HEAT
Setting of outdoor ambient temperature to turn ON
the backup heater.
0 °C -15 °C ~ 20 °C HEATER
Setting of water outlet temperature during
*
1
COOL
mode.
10 °C 5 °C ~ 20 °C
*
1,
*
2
COOL
Setting of sanitary water tank temperature. 52 °C 40 °C ~ 65 °C TANK
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
How to use
F569865-SS0419-2.indb 9F569865-SS0419-2.indb 9 2/5/2019 11:27:01 AM2/5/2019 11:27:01 AM