Operating instructions

-43-
C L O C K S E T
D D . M M M . Y Y H H : M M
1 . J A N . 9 8 1 2 : 1 5
R E S E T
A L L R E S E T = S E T
R E C A L L C L E A R = S E T
7. CLOCK SET
This table is used to set the present time and date.
Move the cursor to CLOCK SET on the SYSTEM menu
by moving the Joystick Controller, then press the CAM
(SET) button to display the CLOCK SET menu as shown
below.
1. Move the cursor to the DD parameter by moving the
Joystick Controller, then enter the desired date by
pressing the Numeric buttons or the +1CAM INC or
–1CAM DEC button.
2. Move the cursor to the MMM parameter by moving
the Joystick Controller, then select the desired
month by pressing the +1CAM INC or –1CAM DEC
button.
3. Move the cursor to the YY parameter by moving the
Joystick Controller, then enter the desired year (last
two digits) by pressing the Numeric buttons or the
+1CAM INC or –1CAM DEC button.
Note: Valid dates are between the year 1998 and
the year 2 096.
Enter “00” for the year of 2 000.
4. Move the cursor to the HH parameter by moving the
Joystick Controller, then enter the desired hours
(military time) by pressing the Numeric buttons or
the +1CAM INC or –1CAM DEC button.
5. Move the cursor to the MM parameter by moving
the Joystick Controller, then enter the desired min-
utes by pressing the Numeric buttons or the
+1CAM INC or –1CAM DEC button.
6. Press the MON (ESC) button to escape from the
programming mode and return to the previous SYS-
TEM menu.
Note: The date and time are updated when the
MON (ESC) button is pressed.
8. RESET
This table is used to reset the system to the initial facto-
ry settings.
Note that this function clears all data setup previously,
so avoid using it unless necessary.
This table can also be used to clear stored alarm
records.
Move the cursor to RESET on the SYSTEM menu by
moving the Joystick Controller, then press the CAM
(SET) button to display the RESET menu as shown
below.
1. Move the cursor to the RECALL CLEAR parameter
by moving the Joystick Controller, then press the
CAM (SET) button.
2. Select YES by pressing the +1CAM INC or –1CAM
DEC button, then press the CAM (SET) button.
All alarm data stored in the logs is cleared.
3. Move the cursor to the ALL RESET parameter by
moving the Joystick Controller, then press the CAM
(SET) button.
4. Select YES by pressing the +1CAM INC or –1CAM
DEC button, then press the CAM (SET) button.
All parameters that have been changed from the ini-
tial factory settings are reset to their initial values.
5. Press the MON (ESC) button to escape from the
programming mode and the system will restart.