System Controller Operating Instructions WV-CU161 ENGLISH Model No.
ENGLISH VERSION Caution: Before attempting to connect or operate this product, please read the label on the bottom. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). For U.S.A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
PREFACE ..................................................................................................................................................................................... FEATURES ................................................................................................................................................................................... PRECAUTIONS .........................................................................................................................
PREFACE The WV-CU161 System Controller is designed for one-to-one use with the Combination Camera such as the WV-CS854/WVCS654/WV-CS604 Combination Camera or the WV-RC100/WV-RC150 Receiver. Camera control is performed by multiplexing the control signal with the video signal by connecting an AV Codec or the like, or via RS-485 site communication*1. Alarm signals, such as motion detector signals, can be supplied to external equipment from a built-in alarm output connector.
PRECAUTIONS • Refer all work related to the installation of this product to qualified service personnel or system installers. • Do not block the ventilation opening or slots on the cover. To prevent the appliance temperature from rising, place the appliance at least 5 cm (2 inches) away from the wall. • Do not drop metallic parts through slots. This could permanently damage the appliance. Turn the power off immediately and refer servicing to qualified service personnel.
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ■ Front View q w OPERATE ALARM u y r t System Controller WV-CU !3 1 SHIFT 2 3 RESET SUSPEND !5 B/W PATROL STOP ALARM !4 4 5 6 7 8 9 DEF AUX1 AUX2 NEAR L R e AUTO FOCUS HOME SLOW CAMERA FUNCTION FAR FOCUS PROGRAM !6 UP PATROL LEARN WIPER CAMERA SETUP SETUP PATROL PLAY AUTO PRESET WIDE ESC TELE DOWN ZOOM 0 CLOSE SET IRIS OPEN IRIS RESET PROGRAM PRESET !2 !0 q Operate Indicator (OPERATE) Lights up while the powe
y Auto Panning/Black and White Selection/Patrol Stop Button (AUTO/B/W/PATROL STOP) AUTO: Pressing this button will activate the auto panning function of cameras provided with this feature. B/W: Pressing this after pressing the SHIFT button will display the picture in black and white on the monitor. PATROL STOP: Pressing this will stop the programming of the camera patrol learning function.
■ Rear View e ALARM RS485 ALARM IN ALARM OUT RECOVER IN RESET OUT T R G B A B A 4 3G2 1 DATA VIDEO OUT TERM LINE ON 4 COAX OFF 2 RS485 CAMERA IN POWER OFF ON SIGNAL GND ALARM IN y t r q u w q Alarm Input Terminal (ALARM IN) Accepts the alarm signals from external devices such as alarm sensor when the alarm switch y is in the upper position. w Alarm Output Terminal (ALARM OUT) The alarm output signal is provided at this terminal for the Time Lapse VCR etc.
SETUP The WV-CU161 can be programmed by setting switches or from the interactive Setup menu as described below. 1. DIP Switch Setting (See page 10) 2. Data Switch Setting For setting the mode of communication between the WV-CU161 and the combination camera. 3. Alarm Switch Setting For setting up the alarm terminal. Turn off the power before setting this switch. 4. Setup of WV-CU161 Display the Setup menu (see page 17) to setup the WV-CU161.
CONNECTIONS Check the DIP switch settings before connecting this controller. They need to be changed only if you want to change the system settings. The following setting procedure should be made by qualified service personnel or system installers. ■ DIP Switch Setting Caution: Unplug the AC cord before changing any DIP switch setting. ● Removing the Bottom Cover for SW1 Remove two screws. 1. Take off the bottom cover by removing the two screws.
SYSTEM CONNECTION The WV-CU161 can be connected with a camera, a video monitor and a Time Lapse VCR. A typical connection example is shown below.
■ Connection with a Video Switcher Connected with a video switcher, the WV-CU161 allows you to control multiple combination cameras.
■ RS-485 Site Communication Connection via Codec for Camera Distance of 1 200 m (4 000 ft) or More RS-485 Cable Coaxial Cable DATA PORT WV-CS854 AV Codec Public lines AV Codec VIDEO OUT DATA PORT System Controller WV-CU OPERATE ALARM 1 2 3 SUSPEND 4 5 6 CAMERA SETUP SERUP 7 8 9 SHIFT CAMERA IN PATROL PAY AUTO B/W UP ALARM RESET WIPER DEF AUX1 AUX2 NEAR RESET CAMERA FUNCTION FAR R L FOCUS AUTO FOCUS PROGRAM HOME PRESET WIDE SET CLOSS 0 ESC TELE IRIS DOWN OPEN IRIS R
■ Connection with a Time Lapse VCR Connect the time lapse VCR as shown in the example below. Make sure the polarity of the buzzer matches the terminal. Connect the positive (+) terminal of the buzzer to the Alarm Output Terminal. The Alarm Output Terminal is an Open Collector terminal with a capacity of 16 V DC, 100 mA or less. (1) Connect the buzzer as shown below if its rating lies within the capacity of the Alarm Output Terminal.
■ RS-485 Terminal Control data is transmitted and received to and from other peripherals. Use a data grade, double-shielded, twisted pair cable, suitable for the RS-485. Cable length may be extended up to 1 200 m (4 000 ft).
SETUP MENU The Setup menu has four main submenus: Alarm Setup, System Setup, Preset Data Load, and Communication. All of these main menus are further divided into submenus. SETUP MENU ALARM SETUP*1 ALARM TERMINAL SYSTEM SETUP*2 PRESET DATA LOAD*3 PRESET DATA LOAD CAM 1 PRESET DATA LOAD CAM 2 PRESET DATA LOAD CAM 3 PRESET DATA LOAD CAM 4 PRESET DATA LOAD CAM 5 PRESET DATA LOAD CAM 6 PRESET DATA LOAD CAM 7 PRESET DATA LOAD CAM 8 COMMUNICATION*4 *1 To set the alarm operation mode when an alarm is activated.
■ Displaying the Setup Menu 1. Check that the camera, the monitor and peripherals are connected correctly and securely. 2. Switch all the system components on. The operate indicator of the WV-CU161 lights up. The picture of the camera appears on the monitor. 3. Press the SHIFT button, and then press the CAMERA SETUP/SETUP button for 2 seconds or more. 4. The SETUP MENU appears. • Joystick Controller L R Up: To select modes. R Down: To select modes. R Left: To decrease the parameter.
• For using alarm input terminals 1-4 ALARM SETUP ALARM DISPLAY ON SITE ALARM ON TERM.ALARM ON ALARM OUTPUT 10S ALARM BUZZER ON ALARM TERMINAL (1) Alarm Display Setting This item lets you select whether or not the message ALARM on the monitor when the alarm is activated. 1. Display the ALARM SETUP menu. 2. Select ALARM DISPLAY by moving the joystick up or down. 3. To have ALARM displayed, select ON for the ALARM DISPLAY parameter. Otherwise select OFF by moving the joystick to the right or left.
• For using alarm input terminals 1-4 ALARM SETUP ALARM DISPLAY ON SITE ALARM ON TERM.ALARM ON ALARM OUTPUT 10S ALARM BUZZER ON ALARM TERMINAL ■ System Setup 1. Display the Setup menu. 2. Select SYSTEM SETUP by moving the joystick up or down. 3. Press the PRESET/SET/PROGRAM PRESET button. The SYSTEM SETUP menu appears on the monitor as shown below. SYSTEM SETUP 1. Display the ALARM SETUP menu. 2. Select ALARM TERMINAL by moving the joystick up or down. 3. Press the PRESET/SET/PROGRAM PRESET button.
■ Preset Data Load Setting 1. Display the Setup menu. 2. Select PRESET DATA LOAD by moving the joystick up or down. 3. Press the PRESET/SET/PROGRAM PRESET button. The PRESET DATA LOAD screen appears on the monitor as shown below. PRESET DATA LOAD CAM1: CAM2: CAM3: CAM4: CAM5: CAM6: CAM7: CAM8: P : Data saved. ■ : No Data saved. (CAM1 - CAM8 of the initial factory setting are marked all ■.) (1) Download Setting 1. Display the PRESET DATA LOAD menu. 2.
(2) Upload Setting 1. Display the PRESET DATA LOAD menu. 2. Select a camera number between CAM1 and CAM8 by moving the joystick up or down. 3. Press the PRESET/SET/PROGRAM PRESET button. 4. The camera number and upload menu appear on the monitor as shown below. • In case of RS-485 Site Communication mode, check that the unit address is the same as set on the combination camera. If the numbers do not agree, the camera cannot be operated. Therefore, preset data cannot be uploaded.
9. To return to the preset data menu, press the HOME/ESC button after completing the data title setting. To replace a specific character 1. Use the joystick to shift the cursor to the selected character area. 2. Move the cursor to the character to be replaced by moving the joystick right or left. 3. Move to shift the cursor to the character area by moving the joystick up or down, and move the cursor to the desired character by moving the joystick up, down, right or left. 4.
(4) Parity Check Setting This item lets you set the parity bit for RS-485 communication. 1. Display the COMMUNICATION menu. 2. Select PARITY CHECK by moving the joystick up or down. 3. Select NONE, EVEN or ODD for parity check by moving the joystick to the right or left. The initial factory setting is NONE. Note: This setting must be compatible with the peripherals connected. (5) Stop Bit Setting This item lets you set the number of stop bits for RS-485 communication. 1. Display the COMMUNICATION menu. 2.
OPERATING PROCEDURES CAMERA CONTROL FUNCTIONS It is necessary to setup the camera before using the camera control functions. For further information, refer to the Operating Instructions for the respective combination camera (See page 30). You can also set it up from Camera Setup menu if you operate a system. ■ Lens Control The following functions are available with cameras provided with controllable lens. 1. Press the FOCUS NEAR or FOCUS FAR button to adjust the lens focus while watching the monitor.
■ Operation of Combination Camera ● Auto Pan It is necessary to setup the combination camera before operating it. For further setup information, refer to the Operating Instructions for the combination camera (See page 30). You can also set it up from the Camera Setup menu if you operate a system. The following functions are available only with cameras provided with the pan/tilt head specified for this operation. It is necessary to program auto pan function for the combination camera beforehand. 1.
● Camera Patrol Function The following function is available with combination cameras provided with the camera patrol function. The camera patrol function enables the combination camera to learn joystick movements and zooming operation. To program the camera patrol learning function, see page 31. 1. Press the PATROL PLAY/PATROL LEARN button to move the combination camera according to the data saved in the memory.
2. Press the SLOW/CAMERA FUNCTION button after pressing the SHIFT button. SLOW • Electronic Sensitivity Enhancement The following function is available only with cameras provided with the electronic sensitivity function. 1. Press numeric buttons 1, 7 and 7. CAMERA FUNCTION SHIFT 3. To cancel the electronic shutter function, press numeric buttons 1, 7 and 2. 1 2 3 4 5 6 7 8 9 HOME 4. To increase electronic shutter speed, press numeric buttons 1, 7 and 3. PRESET 0 ESC SET PROGRAM PRESET 5.
■ Camera Housing Control ■ External Device Control ● Wiper Control ● Auxiliary Control The following function is available only with the cameras whose housing is provided with the wiper control function. The following function is available only in cases where external devices are connected to the receiver or the camera. 1. Press the WIPER/AUX1 button to operate the wiper on the selected camera. WIPER 1.
ALARM CONTROL FUNCTIONS ■ Alarm Reset When the WV-CU161 receives an alarm signal from a camera site, an alarm is activated. The WV-CU161 can handle the following alarms. Manual or Automatic resetting can be selected. When the alarm is reset, [ALARM] disappears from the monitor screen and the alarm reset signal is output from the alarm terminal on the rear panel. ● Camera Site Alarm Coaxial Multiplex Communication: Alarm is multiplexed with video signals from the camera.
CAMERA SETUP You can use the WV-CU161 to setup the camera from the Camera Setup menu. For further information, refer to the Operating Instructions for the individual combination cameras. Notes: • To display the special menu, move the cursor to [SPECIAL] on the Setup menu, and press numeric buttons 4 and 6 simultaneously for 2 seconds or more. • To restore all defaults, move the cursor to [CAMERA RESET]* on the Setup menu, and press buttons 4, 5 and 6 simultaneously for 2 seconds or more. ● Camera Setup 1.
● Camera Patrol Learning for Camera Patrol Operation The camera patrol learning function can be setup either from the Camera Setup menu or while operating the camera. Follow the procedures below to setup the function for a connecting combination camera. ● Preset Position Setting Preset positions can be programmed either from the Camera Setup menu or from the System Controller. The following functions are available with the respective functions. 1.
INSTALLATION The installation should be made by qualified service personnel or system installers according to the following instructions. ■ Mounting in the Rack Note: Keep the Power On/Off Switch turned off while making the following installations. 1. Remove the Connector Panel and Bottom Cover from the controller by removing the four screws. Remove Connector Panel 2. Mount the Connector Panel onto the bottom by using the two screws removed above. Bottom Cover 3.
ALL RESET The System Controller WV-CU161 can be reset to the default settings as follows: 3. When all LEDs light up for a few seconds and go off (except for the Operate Indicator), resetting is completed. 1. Turn off the Power Switch. 2. Turn on the Power Switch while pressing numeric buttons 2, 4 and 6 simultaneously. 1 2 3 4 5 6 7 8 9 HOME PRESET 0 ESC SET PROGRAM PRESET 33 Note: The downloaded data for the camera remains as it is.
SPECIFICATIONS Power Source: Power Consumption: Camera Input: Alarm Input: Alarm Recover Input: Video Output: Alarm Output: Alarm Reset Output: Data Input/Output: Lens Control: Pan/Tilt Control: Housing Control: Camera Control: Alarm: Ambient Operating Temperature: Ambient Operating Humidity: Dimensions: Weight: 120 V AC, 60 Hz 6W Composite Video Signal: 1 V[p-p]/75 Ω No-voltage contact No-voltage contact Composite Video Signal: 1 V[p-p]/75 Ω Open collector output: 16 V DC, 100 mA max.
Panasonic Security and Digital Imaging Systems Company A Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 Panasonic Canada Inc.
System Controller Operating Instructions WV-CU161 ENGLISH Model No.
VERSION FRANÇAISE (FRENCH VERSION) Précaution: Avant le branchement ou l'utilisation de cet appareil, veuillez lire les instructions inscrites sur l'étiquette collée au fond. CAUTION ATTENTION ATTENTION: AFIN DE PRÉVENIR LE RISQUE DE CHOCS ÉLECTRIQUES, NE PAS RETIRER LES VIS. TOUTE RÉPARATION DEVRAIT ÊTRE CONFIÉE À UN PERSONNEL QUALIFIÉ. Le symbole de l'éclair dans un triangle équilatéral indique la présence d'une tension suffisamment élevée pour engendrer un risque de chocs électriques.
TABLE DES MATIÈRES PRÉFACE .................................................................................................................................................................................... 37 CARACTÉRISTIQUES DOMINANTES ......................................................................................................................................... 37 MESURES DE PRÉCAUTION ..............................................................................................................
PRÉRACE Le contrôleur de système WV-CU161 a été conçu pour être utilisé individuellement avec une caméra vidéo de surveillance combinée tele que le modèle WV-CS854, WV-CS654 ou WV-CS604 ou un récepteur WV-RC100 ou WV-RC150. La commande de caméra vidéo de surveillance est accomplie par multiplexage du signal de commande au signal vidéo après raccordement d'un Codec AV ou d'un appareil simulaire ou encore par l'intermédiaire de la communication site RS485*1.
MESURES DE PRÉCAUTION • Tous les travaux d'installation pour cet appareil doivent être confiés à des techniciens qualifiés ou des installateurs de système confirmés. • Ne pas obturer les ouvertures d'aération ni les fentes du couvercle de l'appareil. Pour empêcher que la température intérieure de l'appareil augmente, écarter l'appareil du mur d'au moins 5 cm (2 pouces). • Ne jamais faire tomber d'objets métalliques par les fentes d'aération. En effet, cela risque d'endommager définitivement l'appareil.
PRINCIPAUX ORGANES DE COMMANDE ET LEURS FONCTIONS ■ Vue de la face avant q w OPERATE ALARM u y r t System Controller WV-CU !3 1 SHIFT 2 3 !4 SUSPEND !5 B/W PATROL STOP ALARM RESET 4 5 6 7 8 9 DEF AUX1 AUX2 L R e FOCUS AUTO FOCUS HOME SLOW CAMERA FUNCTION FAR NEAR PROGRAM !6 UP PATROL LEARN WIPER CAMERA SETUP SETUP PATROL PLAY AUTO PRESET WIDE ESC TELE DOWN ZOOM 0 CLOSE SET IRIS OPEN IRIS RESET PROGRAM PRESET !2 !0 q Lampe-témoin d'alimentation (OPERATE)
B/W: Le fait d'appuyer sur cette touche après avoir pressé la touche SHIFT permet de faire apparaître les images en noir et blanc sur l'écran du moniteur vidéo. PATROL STOP: Le fait d'appuyer sur la touche a pour effet d'interrompre la programmation de la fonction didactique de patrouille de caméra vidéo de surveillance.
■ Vue de la face arrière e ALARM RS485 ALARM IN ALARM OUT RECOVER IN RESET OUT T R G B A B A 4 3G2 1 DATA VIDEO OUT TERM LINE ON 4 COAX OFF 2 RS485 CAMERA IN POWER OFF ON SIGNAL GND ALARM IN y t r q u w q Borne d'entrée d'alarme (ALARM IN) Elle accepte les signaux d'alarme provenant d'appareils extérieurs tels les détecteurs d'alarme lorsque le sélecteur d'alarme y est en position haute.
CONFIGURATION Le WV-CU161 peut être programmé en positionnant les commutateurs de façon appropriée ou à partir des paramètres de réglage du menu de configuration interactif comme décrit ci-dessous. 1. Réglage des interrupteurs à positions multiples (DIP) (se reporter à la page 43) 2. Réglage du commutateur de données Permet de sélectionner le mode de communication entre le WV-CU161 et la caméra vidéo de surveillance combinée. 3. Réglage de commutateur d'alarme Permet de régler la borne d'alarme.
BRANCHEMENTS Vérifier le positionnement des interrupteurs DIP avant d'effectuer le raccordement du contrôleur. La position des interrupteurs ne doit être modifiée que si des modifications sont à apporter aux réglages du système. La procédure de réglage mentionnée ci-dessous doit être confiée à un dépanneur professionnel ou à des installateurs de système qualifiés.
BRANCHEMENT DE SYSTÈME Le WV-CU161 peut être raccordé à une caméra vidéo de surveillance, un moniteur vidéo et un magnétoscope d'enregistrement longue durée. Un exemple de raccordement caractéristique est indiqué ci-dessous.
■ Raccordement à un commutateur cyclique vidéo Une fois raccordé à un commutateur cyclique vidéo, le WV-CU161 vous permet de piloter plusieurs caméras vidéo de surveillance combinées.
■ Raccordement de communication de site RS-485 par Codec pour une distance d'éloignement à une caméra vidéo de surveillance égale ou supérieure à 1 200 m (4 000 pd.
■ Raccordement à un magnétoscope d'enregistrement longue durée Raccorder le magnétoscope d'enregistrement longue durée en procédant de la façon représentée sur la figure ci-dessous fournie en exemple. Vérifier que la polarité de la sonnerie correspond avec celle de la borne. Raccorder la borne positive (+) de la sonnerie à la borne de sortie d'alarme. La borne de sortie d'alarme est une borne de 16 V c.c., 100 mA ou moins.
■ Borne RS-485 Les données de commande destinées et provenant des périphériques sont transmises et reçues par l'intermédiaire de cette borne. Faire en sorte d'utiliser des câbles de transmission de données de très bonne qualité, blindés à double conducteur et paire torsadée adaptés à une connexion RS-485. La longueur du câble peut être prolongée au-delà de 1 200 m (4 000 pd.).
MENU DE CONFIGURATION Le menu de configuration est constitué de quatre menus principaux: menu de configuration d'alarme, menu de configuration de système, chargement de données présélectionnées et communication. Tous ces menus principaux sont divisés en sous-menus.
■ Affichage du menu de configuration 1. Vérifier que la caméra vidéo de surveillance, le moniteur vidéo et les appareils périphériques sont raccordés correctement et que les branchements sont parfaits. 2. Mettre tous les composants constitutifs du système sous tension. La lampe témoin du WV-CU161 s'allume. Les images de la caméra vidéo de surveillance apparaissent sur l'écran du moniteur vidéo. 3. Appuyer sur la touche SHIFT, puis sur la touche CAMERA SETUP/SETUP pendant au moins 2 secondes. 4.
• Pour pouvoir utiliser les bornes d'entrée d'alarme 1-4 ALARM SETUP ALARM DISPLAY ON SITE ALARM ON TERM.ALARM ON ALARM OUTPUT 10S ALARM BUZZER ON ALARM TERMINAL (1) Réglage d'affichage d'alarme Ce paramètre vous permet de sélectionner si le message ALARM doit être affiché sur l'écran du moniteur vidéo ou non quand une alarme se déclenche. 1. Faire apparaître le menu de configuration ALARM SETUP. 2. Choisir ALARM DISPLAY en actionnant la manette de réglage tous azimuts vers le haut ou vers le bas. 3.
Remarque: Le paramètre ALARM PRESET n'est disponible que dans la mesure où une caméra vidéo de surveillance combinée est raccordée. • Pour pouvoir utiliser les bornes d'entrée d'alarme 1-4 ALARM SETUP ALARM DISPLAY ON SITE ALARM ON TERM.ALARM ON ALARM OUTPUT 10S ALARM BUZZER ON ALARM TERMINAL ■ Configuration de système 1. Faire apparaître le menu de configuration. 2. Choisir le menu SYSTEM SETUP en actionnant la manette de réglage tous azimuts vers le haut ou vers le bas. 3.
■ Réglage de chargement de données présélectionnées 1. Faire apparaître le menu de configuration. 2. Choisir PRESET DATA LOAD en actionnant la manette de réglage tous azimuts vers le haut ou vers le bas. 3. Appuyer sur la touche PRESET/SET/PROGRAM PRESET. Ceci a pour effet de faire apparaître la page-écran PRESET DATA LOAD sur l'écran du moniteur vidéo comme représenté sur la figure ci-dessous. PRESET DATA LOAD CAM1: CAM2: CAM3: CAM4: CAM5: CAM6: CAM7: CAM8: P : Données sauvegardées.
(2) Réglage de téléchargement 1. Faire apparaître le menu PRESET DATA LOAD. 2. Choisir un numéro de caméra vidéo de surveillance parmi les numéros CAM1 à CAM8 en actionnant la manette de réglage tous azimuts vers le haut ou vers le bas. 3. Appuyer sur la touche PRESET/SET/PROGRAM PRESET. 4. Ceci a pour effet de faire apparaître le menu de numéro de caméra vidéo de surveillance et de téléchargement sur l'écran du moniteur vidéo comme représenté sur la figure ci-dessous.
6. Amener le curseur sur la position qui correspond à la zone de caractère désirée en actionnant la manette de réglage tous azimuts vers la droite ou vers la gauche. 7. Appuyer sur la touche PRESET/SET/PROGRAM PRESET. 8. Refaire la procédure indiquée de 6 à 7 jusqu'à ce que tous les caractères soient édités. Il est possible de sélectionner jusqu'à 12 caractères. 9. Appuyer sur la touche HOME/ESC pour retourner au menu de données présélectionnées après avoir fait le réglage de données présélectionnées.
(4) Réglage de contrôle de parité Ce paramètre vous permet de définir le bit de parité pour une communication RS-485. 1. Faire apparaître le menu COMMUNICATION. 2. Choisir le paramètre PARITY CHECK en actionnant la manette de réglage tous azimuts vers le haut ou vers le bas. 3. Choisir le type de contrôle de parité désiré NONE, EVEN ou ODD en actionnant la manette de réglage tous azimuts vers la droite ou vers la gauche. Le réglage usine initial a été fait sur NONE.
PROCÉDURES D'UTILISATION FONCTIONS DE COMMANDE DE CAMÉRA VIDÉO DE SURVEILLANCE La configuration de caméra vidéo de surveillance doit être faite au préalable avant de pouvoir utiliser les fonctions de caméra vidéo de surveillance. Relire la notice d'instructions correspondante de la caméra vidéo de surveillance combinée pour savoir comment effectuer la configuration de celle-ci. (Se reporter à la page 63).
■ Utilisation d'une caméra vidéo de surveillance combinée La configuration de la caméra vidéo de surveillance combinée doit être faite au préalable avant de pouvoir l'utiliser. Relire la notice d'instructions correspondante de la caméra vidéo de surveillance combinée pour savoir comment effectuer la configuration de celle-ci. (Se reporter à la page 63).
● Fonction de patrouille de caméra vidéo de surveillance La fonction suivante n'est disponible que dans la mesure ou une caméra vidéo de surveillance combinée et dotée de la fonction de patrouille de caméra vidéo de surveillance est raccordée. La fonction de patrouille de caméra vidéo de surveillance permet à une caméra vidéo de surveillance combinée de mémoriser les mouvements de la manette de réglage tous azimuts et les réglages de cadrage.
3. La fonction d'obturateur électronique est annulée en appuyant sur les touches numériques 1, 7 et 2. 2. Appuyer sur la touche SLOW/CAMERA FUNCTION après avoir pressé la touche SHIFT. 4. La vitesse d'obturation électronique peut être augmentée en appuyant sur les touches numériques 1, 7 et 3. SLOW CAMERA FUNCTION SHIFT 5. La vitesse d'obturation électronique peut être diminuée en appuyant sur les touches numériques 1, 7 et 4.
■ Commande de compartiment de caméra vidéo ■ Commande d'un appareil extérieur ● Commande d'essuie-glace La fonction décrite ci-après n'est disponible que dans la mesure où des appareils séparés sont raccordés au récepteur ou à la caméra vidéo de surveillance. Cette fonction n'est disponible que dans la mesure ou un compartiment étanche de caméra vidéo équipé de la fonction de commande d'essuie-glace est raccordé au système. 1.
FONCTIONS DE CONTRÔLE D'ALARME Lorsque le WV-CU161 reçoit des signaux d'alarme d'un site de caméra vidéo, une alarme se déclenche. Le WV-CU161 peut prendre en charge les types d'alarmes suivants. ● Alarme de site de caméra vidéo de surveillance Communication coaxiale multiplex: Alarme multiplexée aux signaux vidéo provenant de la caméra vidéo de surveillance. Communication de site RS-485 Alarme transmise par l'intermédiaire de RS-485.
CONFIGURATION DE CAMÉRA VIDÉO DE SURVEILLANCE La configuration de caméra vidéo de surveillance peut être faite avec le WV-CU161 à partir du menu de configuration de caméra vidéo de surveillance. Relire la notice d'instructions correspondante des caméras vidéo de surveillance combinées individuelles pour obtenir des explications plus détaillées à ce sujet. ● Configuration de caméra vidéo de surveillance 1.
● Didactique de patrouille de caméra vidéo de surveillance de commande de patrouille de caméra vidéo de surveillance La configuration de la fonction didactique de patrouille de caméra vidéo de surveillance peut être faite soit à partir du menu de configuration de caméra vidéo de surveillance, soit en commandant la caméra vidéo de surveillance en service. Voici les procédures qui permettent d'effectuer la configuration quand une caméra vidéo de surveillance combinée est en service.
INSTALLATION Les travaux suivants doivent être exécutées par un dépanneur professionnel ou des installateurs de système qualifiés conformément aux instructions suivantes. ■ Installation en bâti Remarque: Conserver l'interrupteur d'alimentation en position d'arrêt pendant les opérations d'installation décrites ci-après. 1. Retirer le panneau des connecteurs et la plaque de fond du contrôleur en retirant les quatre vis de fixation. Retirer Panneau des connecteurs 2.
REMISE À ZÉRO GÉNÉRALE Le contrôleur de système WV-CU161 peut être remis à zéro et ramené sur tous ses réglages d'origine par défaut. 1. Commuter l'interrupteur d'alimentation sur sa position d'arrêt. 2. Mettre sous tension avec l'interrupteur d'alimentation tout en appuyant simultanément sur les touches numériques 2, 4 et 6. 1 2 3 4 5 6 7 8 9 HOME PRESET 0 ESC SET PROGRAM PRESET 66 3.
CARACTÉRISTIQUES TECHNIQUES Source d'alimentation: Puissance consommée: Entrée de caméra: Entrée d'alarme: Entrée de rétablissement d'alarme: Sortie vidéo: Sortie d'alarme: Sortie de rétablissement d'alarme: Entrée ou sortie de données: Commande d'objectif: Balayage panoramique ou réglage d'inclinaison: Compartiment de caméra vidéo: Commandes de caméra vidéo de surveillance: Alarme: Limites de température ambiante: Taux d'humidité ambiante: Dimensions: Poids: 120 V c.c.
Panasonic Security and Digital Imaging Systems Company A Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 Panasonic Canada Inc.