Operating Instructions

14
4
Connet the cable of control terminal to all control terminals.
Control Terminals
NAME I/O NOTICE
1 ZOOM (TELE: +, WIDE: -) IN TELE (+3 V - +15 V) WIDE (-3 V - -15 V)
2 FOCUS (NEAR: +, FAR: -) IN NEAR (+3 V - +15 V) FAR (-3 V - -15 V)
3 IRIS (OPEN: +, CLOSE: -) IN OPEN (+3 V - +15 V) CLOSE (-3 V - -15 V)
4 COM (For ZOOM, FOCUS, IRIS)
5 ALARM OUT
Open collector-output max.16 V DC 100 mA
OFF (OPEN)/ON (0 V)
6 DAY/NIGHT IN Pulled up to 5.0 V DC
OFF (open or 4 V DC-5 V DC)/ON (0 V 0.2 mA)
7 GND (For ALARM, DAY/NIGHT)
8 RS485 (B) I/O
9 RS485 (A) I/O
Lens Control Terminal
Control is possible from external equipment by changing ZOOM, FOCUS, and IRIS to "+" or "-".
<Internal Connection Diagram>
* If you use a lens control terminal, you should not use GND but the COM terminal.
* The COM terminal is used in common with ZOOM, FOCUS, and IRIS.
*
To change the polarity of "+" or "-", make a changeover with the "ZOOM INVERSE" or "FOCUS
INVERSE" on the setup menu.
Alarm Output Terminal
Connect an external device such as a buzzer or lamp to the ALM OUT terminal.
DAY/NIGHT Input Terminal
Connect an external sensor to the DAY/NIGHT IN terminal.
Note:
Use a relay unit if the voltage or current of the connected device exceeds the rating.
To validate the Day/Night function, set "BW MODE" to "EXT" on the setup menu.
The GND terminal comes in only one.
If multiple GND lines are required, branches should be made outside the equipment.
ZOOM
FOCUS
IRIS
COM
external
controller etc.
3.6
3.6
3.6