Instruction Manual 2in1 LAN Tester & Multimeter PAN LAN 1 Dipl.Ing. Ernst KRYSTUFEK GmbH & Co KG AUSTRIA, 1230 Vienna, Pfarrgasse 79 Tel: +43/ (0)1/ 616 40 10, Fax: +43/ (0)1/ 616 40 10 – 21 www.krystufek.at office@krystufek.
Contents 1. Introduction............................................... 2. Features................................................... 3. Safety Precautions……………………….. 4. Meter Description..................................... 5. Electrical Specification............................. 6. Operation………………………………….. 7. AutoRanging Multimeter…………………. 8. Multi-Network Modular Cable Tester…… 1.
• Autoranging with auto power off for multimeter functions 3. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present. Double insulation Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before operating the meter. 2.
7. Continuity tests. Remove the battery from the meter if the meter is to be stored for long periods. 4. Meter Description LANtester part Description (1~9) : 1. Remote terminator with LED display for receiving end 2. Jack RJ45 3.
4. 5. 6. Jack RJ45 Jack RJ45 Led display for sourcing end (Jack 1) & Led display for receiving end (Jack 2) 7. Test switch for auto scan 8. LAN tester Power switch 9. Test switch for manual scan Digital multimeter part Description (10~17) : 10. 11. 12. 13. 14. 15. 16. 17. Function switch 3 1/2 Digit (2000 count)LCD display for DMM functions MODE button MAX Hold button Data Hold button COM input jack V, Ω,uA,mA input jack Battery Cover 5.
AC Current Resistance 200.0µA, 2000µA 20.00mA, 200.0mA 200.0Ω ±(1.8% rdg + 8d) ±(2.5% rdg + 8d) ±(0.8% rdg + 5d) 2.000kΩ, ±(1.2% rdg + 3d) 20.00kΩ, 200.0kΩ 2.000MΩ 20.00MΩ ±(2.0% rdg + 5d) ±(5.0% rdg + 8d) Max input voltage Diode Test 600V AC/DC Test current 1mA max., open circuit voltage of 1.5V typical Continuity Check Audible signal if the resistance is <150Ω Display 2000 count 3 -1/2 digit LCD Over range indication LCD displays “OL” Polarity Minus (-) sign for negative polarity.
Standard IEC61010-1 CAT III-600V Pollution degree II, CE Approved 6. Operation AC/DC VOLTAGE MEASUREMENTS CAUTION: Do not measure AC/ DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. 2. 3. 4. Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. Set the function switch to VAC or VDC position. Connect the test leads in parallel to the circuit under test.
RESISTANCE MEASUREMENT WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords. 1. Set the function switch to the Ω position. 2. Insert the black test lead into the negative COM terminal and the red test lead into the positive Ω terminal. 3. Touch the test probe tips across the circuit or part under test.
“OL”. Shorted devices will indicate near 0V and an open device will indicate “OL” in both polarities MAX Hold button To hold the highest reading on the LCD 1. Press the MAX hold button. The meter reading will not change as readings change 2. Press the MAX hold button again to return to normal operation. Hold Button The Data Hold function allows the meter to “freeze” a measurement for later reference 1. Press the “DATA HOLD” button to “freeze” the display, the “HOLD” indicator will appear. 2.
5. 6. 7. 8. 9. Lift the center circuit board straight up from the connectors to gain access to the fuse holders. Gently remove the old fuse and install the new fuse into the holder. Always use a fuse of the proper size and value (0.2A/250V fast blow for the 200mA range). Align the center board with the connectors and gently press into place. Replace and secure the rear cover, battery and battery cover. 8. Multi-Network Modular Cable Tester Operation Note: Make sure the battery power is sufficient.
RJ11 Modular Cable Test Please follow directions for the UTP/STP Cable Test anduse the operations manual for the correct LED pin out display Coaxial Cable Test 1.Plug the two attached BNC adapter cables on both RJ45 jacks. Then connect the tested cable to each end of the BNC adapter cables 2. For the remaining testing procedures, please refer to 10Base-T Test steps 2 to 5. Note: 1. The center pin of BNC should be read on LED 2. 2.
Sample Test Results 12345678G 1. Continuity: Pin 2 has continuity 12345678G 2. Open: Pin 2 is opened 12345678G 3. Short: Pin 2 and Pin 3 are shorted 12345678G 4. Miswire: Pin 3 and Pin 6 are miswired Caution: 1. Operating the tester in live circuits may damage the tester 2.