User Manual

5
Max input voltage 600V AC/DC
Diode Test current 1mA max., open circuit voltage of
1.5V typical
Continuity Check
Audible signal if the resistance is <150
Ω
Display 2000 count 3 -1/2 digit LCD
Over range indication LCD displays “OL”
Polarity Minus (-) sign for negative polarity.
Low Battery Indication “BAT” symbol indicates low battery
condition.
Input Impedance >7.5M (VDC & VAC)
AC Response Average responding
ACV Bandwidth 50Hz to400Hz
Auto Power Off 15 minutes (approximately)
Fuse mA, µA ranges; 0.2A/500V fast acting
Resettable Fuse
Batteries Two 1.5V AAA
Operating
Temperature
32
o
F to 104
o
F (0
o
C to 40
o
C)
Storage Temperature 14
o
F to 122
o
F (-10
o
C to 50
o
C)
Weight 145g
Size 104x55x32.5mm
Standard IEC1010 CAT III 1000V Pollution
degree II, CE Approved