User Manual

6
Operation
AC/DC VOLTAGE MEASUREMENTS
CAUTION: Do not measure AC/ DC voltages if a motor
On the circuit is being switched ON or OFF. Large voltage
surges may occur that can damage the meter.
1. Set the function switch to the green V position.
2. Press the MODE button to indicate “DC” or “AC” on the display.
3. Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to the positive side of the circuit.
4. Read the voltage in the display
DC/AC CURRENT MEASUREMENTS
1. Set the function switch to the µA/mA position.
2. For current measurements up to 2000uA DC/AC, set the function
switch to the mA position
3. Press the MODE button to indicate “DC” / “AC” on the display.
4. Remove power from the circuit under test, then open up the
circuit at the point where you wish to measure current.
5. Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to the positive side of the circuit.
6. Apply power to the circuit.
7. Read the current in the display
NOTE: 0.2A/500V fast acting Resettable Fuse current inputs
and Overload protection on mA, µA ranges. No replacement
required.