(Symbol) Agency Complies with: Requirement Applicable Products
Underwriters
Laboratories, Inc.
File No. E147128
UL 1565
CSA C22.2 No.18.5-02
“Positioning Devices.
Wiring duct types:
H, HS, HN, and DRD
Underwriters
Laboratories, Inc.
File No. E147128 UL 1565 All types of wiring duct
Canadian Standards
Association
File No. 016446
CSA C22.2 No.18.5-02
“Positioning Devices.
All types of wiring duct
(except DRD, H, HN, HS)
Conformite European
Low Voltage Directive
2006/95/EEC
EN50085 cable trunking system and cable
ducting systems for electrical installations
• CDS (cable ducting system
for impact 2 J)
• Minimum storage and transport
temperature -5°C
• Minimum installation and application
temperature -5°C
• Maximum application temperature 60°C
• Non-flame propagating
Without electrical continuity
• Cover removable without a tool
Wiring duct types:
H, HS, G, F, D, MC, FS,
NNC, NE, and DRD
Logo
(Symbol) Agency Complies with: Requirement Applicable Products
DIN (Deutsches
Institut fur Normung),
German Institute
for Standardization
DIN 43 659
This European standard specifies
dimensions for slotted trunkings that will
be used in electrical switchgear
assemblies and that conform to the
corresponding requirements in DIN VDE
060 Part 506. The dimensions specified
with the standard include:
The channel mounting hole pattern,
slot dimensions, pitch, and location
The distance from the first to last
like size mounting hole
• Minimum overall product length
Wiring duct types:
MC and NNC
National Fire
Protection Agency
NFPA 79-2007,
section 13.3.1
“Non-metallic ducts shall be permitted
(inside enclosures) only when they are
made with a flame retardant material.
Flame-retardant material is defined in the
standard by the IEC 60332-1 test method.
Wiring duct types:
H, G, F, D, MC, NNC,
CWD, HN, and NE
NFPA 79-2007,
section 13.5.2
Panduit wiring duct publishes a maximum
percentage wirefill for common wire types
equal to 50% of the interior
cross-sectional area of the duct.
All types of wiring duct
NFPA 79-2007,
section 13.1.5.9
Panduit bend radius control accessories
can be mounted at right angle and T
junctions created using wiring duct in order
to maintain cable bend radius control.
Duct corner strip with 1"
bend radius control