Information

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
D2.147
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
Part Number
Transformer KVA
Rating
Aluminum
Mechanical Lug
Conductor Size Range
Hardware
(Sizes in Inches)
Part No. Qty. Hex Bolt Size Qty. Nut Size Qty. Washer Size Qty.
KLM14-250Y
15 – 37.5 KVA 1PH
15 – 45 KVA 3PH
LAMA2-14
LAMA250-56
8
4
#14 – 2 AWG
#6 AWG – 250 kcmil
1/4 – 20 x 3/4 HH 8 1/4 – 20 HN 8 1/4 FLAT
1/4 CMP
16
8
KLM6-250Y
50 – 75 KVA 1 PH
75 – 112.5 KVA 3 PH
LAMA250-56 12 #6 AWG – 250 kcmil 1/4 – 20 x 3/4 HH
1/4 – 20 x 2 HH
8
8
1/4 – 20 HN 16 1/4 FLAT
1/4 CMP
32
16
KLM6-600Y
100 – 167 KVA 1PH
150 – 300 KVA 3 PH
LAMA250-56
LAMA600-38
3
3
#6 AWG – 250 kcmil
#4 AWG – 600 kcmil
1/4 – 20 x 3/4 HH
3/8 – 16 x 2 HH
3
16
1/4 – 20 HN
3/8 – 16 HN
3
16
3/8 FLAT
1/4 FLAT
3/8 CMP
1/4 CMP
32
6
16
3
KLM6-800Y
100 – 167 KVA 1 PH
150 – 300 KVA 3 PH
LAM2A350-12
LAM2A800-58
6
7
#6 AWG – 350 kcmil
350 kcmil – 800 kcmil
1/2 – 13 x 2 HH
1/2 – 13 x 2 1/2 HH
5
6
1/2 – 13 HN 11 1/2 FLAT
1/2 CMP
22
11
KLM350-800Y
500 KVA 3 PH LAM2A800-58 15 350 kcmil – 800 kcmil 1/2 – 13 x 2 HH
1/2 – 13 x 2 1/2 HH
7
4
1/2 – 13 HN 11 1/2 FLAT
1/2 CMP
22
11
Kits include all of the connectors and hardware to make a
complete transformer connection in a single convenient package
Lugs are made from high strength, extruded aluminum alloy and
are tin-plated to inhibit corrosion and oxidation
Plated steel cap screws, belleville and flat washers, and hex
nuts are provided to assure that terminal to bus connections
are made using proper hardware resulting in true torque to
pressure performance
Hardware is packaged in a sealed plastic bag to prevent lost
hardware prior to installation
KLM6-800 and KLM350-800 kits include lugs that accommodate
750 kcmil conductors used with large transformers
Lugs are UL Listed and CSA Certified for use up to 600 V and UL
temperature rated 90°C
For Use with Stranded Aluminum or Copper Code Conductors
Type KLM
Transformer Lug Kit
Suffix: HH = Hex Head; HN = Hex Nut; FLAT = Flat Washer; CMP = Compression Washer.
The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155.