Made from high strength extruded aluminum alloy to provide
premium electrical and mechanical performance
Tin-plated to inhibit corrosion
Rounded bottoms to facilitate taping
Solid center barrier prevents contact of dissimilar metal conductors
Wide wire range-taking capability minimizes inventory requirements
UL Listed and CSA Certified for use up to 600 V and UL
temperature rated 90°C
W
For Use with Stranded Aluminum or Copper Code Conductors
Type SR
The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended. See page D2.155.
**Uses slotted screws.
L
H
W
H
W
L
Figure 1 Figure 3Figure 2
H
L
Part Number Figure No.
Conductor Size Range
Figure Dimensions
(In.)
Hex Key
Size
(In.)
Std.
Pkg.
Qty.
Max. Min. L W H
SR-2-XY
1 #2 AWG STR,
#10 AWG SOL
#14 AWG STR,
#14 AWG SOL
1.38 0.50 0.56 ** 10
SR-0-XY
1 1/0 AWG STR,
#10 AWG SOL
#14 AWG STR,
#14 AWG SOL
1.91 0.75 0.75 ** 10
SR-4/0-XY
1 4/0 AWG #6 AWG 2.31 1.00 1.13 5/16 10
SR-250-XY
2 250 kcmil #6 AWG 3.94 1.00 1.13 5/16 10
SR-350-XY
2 350 kcmil #6 AWG 4.19 1.13 1.19 5/16 10
SR-500-3Y
2 500 kcmil 3/0 AWG 5.00 1.37 1.40 3/8 3
SR-750-1Y
2 750 kcmil 250 kcmil 6.25 1.63 1.75 1/2 1
SR-1000-1Y
3 1000 kcmil 500 kcmil 8.69 1.72 1.88 9/16 1