Cable Tie Selection Chart
Follow this step-by-step process to find the cable ties that best suit your application:
Cable Tie Function
1) Select the main function of the cable tie you need:
Bundle = Standard Cable Ties
Re-use = Nylon Releasable Ties*
Identify = Marker and Flag Ties
Mount = Clamp Ties, Push Mount Ties, and Stud Mount Ties
Material Properties
2) Determine the appropriate
material for your application:
Mechanical
Chemical
Thermal
Cable Tie Family
3) Select the cable tie family that
meets your overall needs
*For information on re-usable Hook and Loop Cable Ties, see page B1.85.
Cross Sections: SM = Subminiature, M = Miniature, I = Intermediate, S = Standard, HS = Heavy-Standard, LH = Light-Heavy, H = Heavy, EH = Extra-Heavy.
Check mark indicates material availability in that product line.
Cable Tie Function
Bundle,
Re-use,
Identify,
Mount
Bundle,
Re-use,
Identify,
Mount
Bundle,
Re-use,
Mount
Bundle,
Re-use,
Mount Bundle Bundle
Material
Test
Method
Nylon 6.6
Weather
Resistant
Nylon 6.6
Impact
Modified
Weather
Resistant
Nylon 6.6
Heat
Stabilized
Nylon 6.6
Heat
Stabilized
Nylon 6.6
Heat
Stabilized
Weather
Resistant
Nylon 6.6
Color
Natural
Black Black Black Natural Black
Part Number Suffix
(Material Designation)
No Suffix 0 0 30 39 300
Tensile @ Yield @ 73°F(psi) ISO 527 12,000 12,000 9,700 12,000 12,000 12,000
Water Absorption (24 Hours) ASTM D570 1.2% 1.2% 1.2% 1.2% 1.2% 1.2%
Radiation Resistance (Rads)
1 x 10
5
1 x 10
5
1 x 10
5
1 x 10
5
1 x 10
5
1 x 10
5
Weathering Life Expectancy
(Years)/UV Resistance
1 – 2 7 – 9 7 – 9 4 – 5 1 – 2 7 – 9
Impact Resistance
Salts
Hydrocarbons
(Gas, Oil, Lubricants)
Chlorinated Hydrocarbons
Acids
Bases
Acid Rain
Max. Continuous Use
Temperature (Note 1)
UL 746B
185°F
85°C
185°F
85°C
185°F
85°C
239°F
115°C
239°F
115°C
212°F
100°C
(Note 2)
Min. Application
Use Temperature
EN 50146
-76°F
-60°C
-76°F
-60°C
-76°F
-60°C
-76°F
-60°C
-76°F
-60°C
-76°F
-60°C
Flammability Rating (Note 4) UL 94 V-2 V-2 HB V-2 V-2 V-2
Low Smoke ASTM E662 PASS PASS PASS PASS PASS PASS
Oxygen Index BS ISO 4589 28 28 28 28 28
Halogen-Free IEC 60754-2 Yes Yes Yes Yes Yes Yes
Burning Fume Toxicity BSS-7239 PASS PASS PASS PASS PASS PASS
Heat Deflection
Temperature @ 1.8 Mpa
ASTM D648
ISO 75 -1/-2
158°F
70°C
158°F
70°C
145°F
63°C
158°F
70°C
158°F
70°C
158°F
70°C
Relative Price Low Low Low Low Low Med
Product Line
Cross Sections
Pan-Ty
®
(B1.6 - Note 5) SM, M, I, S LH, H, EH
Super-Grip
®
(B1.38) M, I, S, LH H
Dome-Top
®
Barb Ty (B1.43) M, I, S LH
Dura-Ty
(B1.53)
Parallel-Entry (B1.56) M, I, S, HS LH
Sta-Strap
®
(B1. 65) M, I, S, LH, H
Specialty Ties (B1.73) H
✓✓
✓✓
✓✓