Information

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
D1.43
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
A = Adapter
B = Butted Seam
FB = Metal Insulation
Grip, Female
FI = Fully Insulated,
Female
FIB = Fully Insulated,
Butted Seam, Female
FIM = Fully Insulated, Male
FIMB = Fully Insulated, Male
with Oversized Housing
FL = Locking, Metal
Insulation Grip, Female
M = Male
M B = Butted, Male
P = Piggyback
= Female
(leave blank)
N = Nylon
NF = Nylon,
Funnel Entry
NFR = Nylon,
Funnel Entry,
Right Angle
NG = Nylon,
Funnel Entry,
Metal
Insulation Grip
NH = Heat Shrink
PF = Premium
Grade Nylon,
Funnel Entry
R = Non-insulated,
Right Angle
V = Vinyl
VF = Vinyl
Funnel Entry
= Non-Insulated
(leave blank)
Part Number System for Pan-Term
®
Disconnects
18 = #22 – 18
14 = #16 – 14
10 = #12 – 10
L = 50
C = 100
D = 500
M = 1000
110 = 0.110 x 0.032
111 = 0.110 x 0.020
145 = 0.145 x 0.032
187 = 0.187 x 0.032
188 = 0.187 x 0.020
205 = 0.187/0.205 x 0.032
206 = 0.187/0.205 x 0.020
250 = 0.250 x 0.032
NF
——
14
250
FIB
M
Insulation Wire Range Tab Size Special Configuration Standard Package Size
D
Type
D = Disconnects
Supra-Grip
Female Disconnect, Nylon Fully Insulated Funnel Entry
• Disconnect can be inserted and removed from the male tab
without the use of tools for lower installed cost
• Flared barrel extension integrated into stamping to provide
insulation grip for double crimp requirements
• Fully insulated design provides protection from electrical shorts
• Internal barrel serrations assure good wire contact and maximum
tensile strength
• Internal wire stop assures proper length of insertion into terminal
barrel, providing a higher-quality connection
• Mates with DNF-FIMB family
• UL Flammability UL 94V-2/HB, maximum insulation temperature
221°F (105°C)
• UL and CSA rated up to 600 V per UL 310
*UL Recognized for use with copper alloy tabs.
**Bulk packaging may be available, contact Panduit Customer Service for additional information.
For crimping tool information, see page D1.84.
Type DNG-FB
L
W
H
Part Number
Wire
Range
Color
Code
Max.
Ins.
(In.)
Figure Dimensions
(In.)
Tab
Size
(In.)
Recommended
Installation
Tool
Std.
Pkg.
Qty.**
Std.
Ctn.
Qty.
L W H
DNG18-187FB-C
22 – 18
AWG
Red
0.126 0.89 0.29 0.22 0.187 x 0.032
CT-1015
100 1000
DNG18-188FB-C
0.126 0.89 0.29 0.22 0.187 x 0.020 100 1000
DNG18-250FB-L
0.126 0.93 0.35 0.22 0.250 x 0.032 50 250
DNG14-187FB-L*
16 – 14
AWG
Blue
0.153 0.89 0.29 0.25 0.187 x 0.032
CT-1015
50 250
DNG14-188FB-L*
0.153 0.89 0.29 0.25 0.187 x 0.020 50 250
DNG14-250FB-L
0.153 0.93 0.35 0.25 0.250 x 0.032 50 250