Information

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
D2.105
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
Code/Flex Conductor, with Window, In-Line Reducing Splice
‡See pages D3.76 – D3.81 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
• Low profile design provides minimum space requirements
• Manufactured from seamless, high conductivity copper tubing
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
• Inspection windows in each barrel to visually assure full
conductor insertion
• Generous internally beveled wire entry for easy conductor insertion
Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Also sold as a kit with crystal clear PVC heat shrink (see pages
D2.103, D2.104)
L
B
FROM
B
TO
For Use with Stranded Copper Code and Class I Flex Conductors
Type RSC
Part Number
Copper Conductor
Size
Figure
Dimensions
(In.)
Panduit
Color
Code
Panduit
Die Index
No.
Burndy
Die Index
No.
T&B
Die Index
No.
Wire
Strip
Length
(In.)
Std.
Pkg.
Qty.
B L
RSC4-6-L
Reduces From #4 – 3 AWG STR,#2 AWG SOL 1.05
2.54
Gray P29 8 29 1 1
Reduces To #6 AWG 1.38 Blue P24 7 24 1 5/16
RSC2-6-Q
Reduces From #2 AWG 1.05
2.62
Brown P33 10 33 1 1
Reduces To #6 AWG 1.38 Blue P24 7 34 1 5/16
RSC2-4-Q
Reduces From #2 AWG 1.05
2.50
Brown P33 10 33 1 1
Reduces To #4 – 3 AWG STR,#2 AWG SOL 1.38 Gray P29 8 29 1 5/16
RSC1/0-6-X
Reduces From 1/0 AWG 1.05
2.81
Pink P42 12 42 1 1
Reduces To #6 AWG 1.38 Blue P24 7 24 1 5/16
RSC1/0-4-X
Reduces From 1/0 AWG 1.05
2.70
Pink P42 12 42 1 1
Reduces To #4 – 3 AWG STR,#2 AWG SOL 1.38 Gray P29 8 29 1 5/16
RSC2/0-6-X
Reduces From 2/0 AWG 1.13
2.99
Black P45 13 45 1 1/16 1
Reduces To #6 AWG 1.38 Blue P24 7 24 1 5/16
RSC2/0-4-X
Reduces From 2/0 AWG 1.13
2.88
Black P45 13 45 1 1/16 1
Reduces To #4 – 3 AWG STR,#2 AWG SOL 1.38 Gray P29 8 29 1 5/16
RSC4/0-6-X
Reduces From 4/0 AWG 1.13
3.24
Purple P54 15 54 1 1/16 1
Reduces To #6 AWG 1.38 Blue P24 7 24 1 5/16
RSC4/0-4-X
Reduces From 4/0 AWG 1.13
3.12
Purple P54 15 54 1 1/16 1
Reduces To #4 – 3 AWG STR,#2 AWG SOL 1.38 Gray P29 8 29 1 5/16
RSC4/0-1/0-X
Reduces From 4/0 AWG 1.16
3.13
Purple P54 15 54 1 1/16 1
Reduces To 1/0 AWG 1.63 Pink P42 12 42 1 9/16
RSC4/0-2/0-X
Reduces From 4/0 AWG 1.16
2.90
Purple P54 15 54 1 1/16 1
Reduces To 2/0 AWG 1.50 Black P45 13 45 1 7/16
RSC500-X4/0-6
Reduces From 500 kcmil 1.94
3.97
Brown P87 20 87 1 7/8 1
Reduces To 4/0 Flex 1.50 Yellow P62 16 62 1 7/16
RSC500-X350-6
Reduces From 500 kcmil 1.94
4.38
Brown P87 20 87 1 7/8 1
Reduces To 350 Flex 1.94 Blue P76 19 76 1 7/8
Table continues on page D2.106