Information

ELECTRICAL SOLUTIONS
Prime items appear in BOLD.
D3.24
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
One-Hole Aluminum Lay-In Lug
Type LI
Type CMP
Used for quick installation of a continuous grounding conductor
Made from high strength, extruded aluminum alloy to provide
premium electrical and mechanical performance
Tin-plated to inhibit corrosion
Wide wire range-taking capability minimizes inventory requirements
UL Listed and CSA Certified for use up to 600 V and UL
temperature rated 90°C
H
W
L
Joint Compounds
Oxide inhibitor for compression conductor connections lowers
electrical resistance of compression joint while sealing out air
and moisture to prevent the formation of surface oxides
Wide operating temperature range; can be used in a wide
range of electrical and environmental conditions
Packaged in convenient dispenser bottles
Part Number Part Description
Std.
Pkg.
Qty.
CMP-100-1
Contact aid for pad-to-pad or thread-to-thread aluminum connections, 8 oz. Operating
temperature range -60°F (-51°C) to 400°F (204°C).
1
CMP-200-1
Contact aid for cable connections with compression connections made on aluminum
conductor, 8 oz. Operating temperature range -40°F (-40°C) to 400°F (204°C).
Compatible with all insulating materials.
1
CMP-300-1
Contact aid for copper-to-copper and copper-to-steel connections, 8 oz. Operating
temperature range -40°F (-40°C) to 350°F (177°C). Good for all voltages and suitable
for grounding. Also used for anti-seizing thread lubricant.
1
CMP-300-4-1
Contact aid for copper-to-copper and copper-to-steel connections, 4 oz. Operating
temperature range -40°F (-40°C) to 350°F (177°C). Good for all voltages and suitable
for grounding. Also used for anti-seizing thread lubricant.
1
The use of Panduit oxide inhibiting joint compound (CMP) is recommended for pad to pad and conductor connections. See below.
**Uses slotted head set screw.
Part Number
Conductor Size
Range
Stud Hole
Size (In.)
Hex Key
Size (In.)
Figure Dimensions
In. (mm)
Std.
Pkg.
Qty.
L W H
LI-50S-C
#14 – #4 AWG 0.22 ** 1.07
(27.2)
0.38
(9.7)
0.78
(19.8)
100
LI-112S-L
#14 – 1/0 AWG 0.27 ** 1.50
(38.1)
0.60
(15.2)
1.17
(29.7)
50
LI-252S-Q
#6 AWG – 250 kcmil 0.33 9/16 2.20
(55.9)
0.80
(20.3)
1.79
(45.5)
25