Drawing

THIS
COPY
IS
PROVIDED
ON
A
RESTRICTED
BASIS
AND
IS
NOT
TO
BE
USED
IN
ANY
WAY
DETRIMENTAL
TO
THE
INTERESTS
OF
PANDUIT
CORP.
A
B
A
B
1
2
2
1
N10923BA/20
N10923BA_DC/20A
20 10/17/2019 HPR CLN JADE
Tab
Sizes
corrected
for
-
DNF14-250FIB, DNF14-205FIB, DNF14-206FIB
053133
19
05-22-19
HPR DC JADE
Tab
sizes
added
for
-
DNF18-206FIB, DNF18-188FIB, DNF14-250FIB,
DNF14-206FIB, DNF14-187FIB
046833
18
3-19-19
JEH SKB JADE WAS:
DNF18-205FIBR 045190
17 10.19.12 JBN LCA VMB
ADDED METRIC EQUIVALENT.
UPDATED DRAWING TO CURRENT STANDARDS.
A41196
REV
DATE
BY
CHK
APR
DESCRIPTION
ECN
PANDUIT
PART
#
TAB SIZE
WIRE RANGE
COLOR
MAX. WIRE
INSUL. DIA.
DIMENSIONS in.
[mm]
WIRE
STRIP
LENGTH
ENGLISH METRIC
L
.03
[0,8]
W
.01
[0,3]
H
.02
[0,5]
DNF18-250FIB
.250
X
.032
[6,3
X
0,8]
22-18
0,5-1,0
RED .14
[3,6]
.84
[21,3]
.35
[8,9]
.22
[5,6]
9/32
+1/32
-0
[
7,1
+0,8
-0
]
DNF18-205FIB
.205/.187
X
.032
[5,2/4,8
X
0,8]
.78
[19,8] .31
[7,9]
.22
[5,6]
DNF18-206FIB
.205/.187
X
.020
[5,2/4,8
X
0,5]
.78
[19,8] .31
[7,9]
.22
[5,6]
DNF18-187FIB
.187
X
.032
[4,8
X
0,8]
.78
[19,8]
.29
[7,4]
.16
[4,1]
DNF18-188FIB
.187
X
.020
[4,8
X
0,5]
.78
[19,8]
.29
[7,4]
.16
[4,1]
DNF14-250FIB
.250
X
.032
[6,3
X
0,8]
.16
[4,1]
.84
[21,3]
.35
[8,9]
.22
[5,6]
DNF14-205FIB
.205/.187
X
.032
[5,2/4,8
X
0,8]
16-14
1,5-2,5
BLUE
.78
[19,8] .31
[7,9]
.22
[5,6]
DNF14-206FIB
.205/.187
X
.020
[5,2/4,8
X
0,5]
.78
[19,8] .31
[7,9]
.22
[5,6]
DNF14-187FIB
.187
X
.032
[4,8
X
0,8]
.78
[19,8]
.29
[7,4]
.18
[4,6]
DNF14-188FIB
.187
X
.020
[4,8
X
0,5]
.78
[19,8]
.29
[7,4]
.18
[4,6]
DNF10-250FIB
.250
X
.032
[6,3
X
0,8]
12-10
4,0-6,0
YELLOW
.22
[6,0]
.96
[24,4]
.35
[8,9]
.23
[5,8]
3/8
+1/32
-0
[
9,5
+0,8
-0
]
TITLE
FEMALE DISCONNECTS, NYLON FULLY INSULATED,
FUNNEL ENTRY
CUSTOMER
DRAWING
ITEM
REVISION
NAME
DATASET
FILE
NAME
MATERIAL:
UNLESS
OTHERWISE
SPECIFIED,
DIMENSIONAL
TOLERANCES
ARE:
IN
[mm]
SEE NOTES
.X
.1
[2.54]
.XXX
.005
[.127]
.XX
.01
[.25]
ANGLES
5
DRAWING
NUMBER:
THIRD
ANGLE
PROJECTION
A41196
DRAWN
BY
DATE
CHK
SCALE
SIZE
WJB 01.06.99
-
N.T.S. SHEET 1 OF 1
A
CERTIFIED
LR31212
LISTED
587H
E78522
NOTES:
1. USED FOR:
A.
STRANDED COPPER WIRE ONLY
B. 221 F
[
105 C
]
MAX. OPERATING TEMPERATURE (CSA)
C.
257
F
[
125 C
]
MAX. OPERATING TEMPERATURE (UL)
D.
600V.
MAX. VOLTAGE RATING
2. MATERIAL:
A.
STAMPING: CDA
260
BRASS, TIN PLATED
B. HOUSING:
TYPE
66
NYLON
3. INSTALLATION TOOLS:
A.
UL LISTED AND CSA CERTIFIED:
CT-1525,
CT-2500
(CT-2520CH)
B. PANDUIT APPROVED: CT-100A, CT-160,
CT-260,
CT-600A
(CT-520CH)
3. SEE www.panduit.com FOR PACKAGE QUANTITIES
INDICATED BY PART NUMBER SUFFIX
4. DIMENSIONS IN BRACKETS ARE METRIC EQUIVALENT
5. COLORS ARE TRANSLUCENT.
6. DNF10-250FIB IS UL APPROVED FOR USE WITH THE
FOLLOWING WIRE COMBINATIONS:
(2)
#14,
(2)
#16,
(2)
#18
TWIST WIRES TOGETHER BEFORE CRIMPING
7. INITIAL INSERTION/WITHDRAW FORCE:
6-12
Lb
[27-32
N]
L
H
W
MAX. WIRE
INSUL. DIA.
(SEE CHART)
STAMPING
WIRE AND
RECEPTACLE
SIZES ARE
IDENTIFIED
ON HOUSING
WIRE
CRIMP
AREA
FUNNEL
WIRE ENTRY
HOUSING
WIRE STOP
CURL SLOT
(DNF10-250FIB ONLY)
A
A
DU
I
A
T
N
P