Network Device User's Guide DPOE24U1X, DPOE24U1XY, DPOE12U1X, DPOE12U1XY, DPOE24S1X, DPOE24S1XY

PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2
Part Number: PN378A
48
Message Category Priority
Level
Description
Panel Agent – Cold Start Advisory The main software process (i.e., the panel
agent) in a previously known panel is now
up and running. The process likely reset
itself
New Panel Discovered Advisory The Discover capability has found a new
panel.
PD Connected Minor A new Powered Device has been detected
at the panel.
PD Disconnected Minor A Powered Device has been disconnected.
Panel Power Above Threshold Major The power consumption at the panel has
risen above the Power Warning Threshold.
Panel Power Below Threshold Major The power consumption at the panel has
fallen below the Power Warning Threshold.
Panel Failure Critical The fuse has blown on the power-
forwarding portion of a patch panel.
Port Physical Location Changed Advisory Location information of one of the ports has
changed using the EM.
Trap Recipient Changed Advisory One of the traps associated with a particular
panel was changed using the EM.
PD Detection Failure Major Panel detected failure with one of the
Powered Devices.
Panel Agent Lost Communication Critical EM cannot communicate with the specified
panel.
IP Address Changed Advisory The IP address at one of the panels has
changed using the EM.
Miscellaneous Settings
Several miscellaneous settings must be configured for the
PANDUIT
®
Element Manager to communicate
properly with a deployed network of Power Patch panels.
The
Settings option under the Tools pull-down menu provides an easy mechanism to administer these
settings.