Components

9
visit www.panduit.com/hdflex
HD Flex
Trunk Assemblies
1 – Fiber
F = Fiber
2 –
Fiber Type
9 = OS2 9/125um
X = OM3 50/125µm
Z = OM4 50/125µm
3 – Fiber Count
T = 12 fiber
U = 24 fiber
4 – Cable Type
Y = Indoor small diameter
trunk cable
5 – Jacket Type
L = Low Smoke Zero
Halogen (LSZH)
P = Plenum (OFNP)
6 – Connector Type (End 'A')
5 = Singlemode MPO Female
6 = Singlemode MPO Male
7 = Multimode PanMPO Female
8 = Multimode PanMPO Male
7 – Connector Variant (End 'A')
5 = 39" Breakout with transition
8 – Connector Type (End 'B')
5 = Singlemode MPO Female
6 = Singlemode MPO Male
7 = Multimode PanMPO Female
8 = Multimode PanMPO Male
9 Connector Variant (End 'B')
5 = 39" Breakout with transition
10 Construction/Performance
A = Singlemode Polarity A - Standard IL
X = Multimode Polarity A - Optimized IL
Y = Multimode Polarity B - Optimized IL
K = Multimode Polarity A - Ultra Low IL
L = Multimode Polarity B - Ultra Low IL
11 – Other
N = No pulling eye (15 - 100ft, 5 - 30m)
A = Pulling eye end A (>100ft, > 30m)
12 – Unit of Length
F = Feet (OFNP)
M = Meters (LSZH)
13, 14, 15 – Cable Assembly Length
015 - 300ft 1ft increments to 100ft,
5ft increments to 300ft
005 – 100m, 1m increments
1
F
2
X
3
U
4
Y
5
P
6
7
7
5
8
7
9
5
10
X
11
N
12
F
13
0
14
3
15
0
CHARACTER
EXAMPLE
part number
Example: FXUYP7575XNF030 - OM3 24-ber indoor trunk, plenum, PanMPO™ Female to PanMPO™ Female, 39" break-
outs with HD Flex™ transitions, Method A polarity, optimized IL., no pulling eye, 30 feet.
HD Flex
Harness Assemblies
1 – Fiber Product
F = Fiber
2 –
Fiber Type
9 = Singlemode
X = OM3
Z = OM4
3 – Fiber Count
T = 12-fiber
8 = 8-fiber
4 – Cable Type
R = Round
5 – Jacket Type
L = Low Smoke Zero Halogen
(LSZH)
P = Optical Fiber Nonconductive
Plenum (OFNP)
6 – Connector Type End “A”
5 = Singlemode MPO Female
6 = Singlemode MPO Male
7 = Mulitmode PanMPO
Female
8 = Multimode PanMPO
Male
7 – Connector Variant
N = No variant
8 – Connector Type End “B”
Q = Push/Pull Duplex LC
9 – Connector Variant
S = 24-inch (61 cm)
10 – Performance/Construction
S = Standard IL / Standard Fanout
(Singlemode)
O = Optimized IL / Standard Fanout
(Multimode)
Q = Standard IL / 4-to-1 Conversion
(Singlemode) 8-fiber only
V = Optimized IL / 4-to-1 Conversion
(Multimode) 8-fiber only
N = Ultra Low IL/Standard Fanout
(OM4 Only)
11 – Other
N = No variant
12 – Unit of Length
M = Meters
F = Feet
13, 14, 15 – Length
Meters: 001 to 010, 1.5, 2.5, 3.5, 4.5
Feet: 003 to 030
part number
Example: FZTRP8NQSONF003 = Fiber OM4, 12-ber, round, plenum rated, PanMPO male to Push/Pull duplex LC harness
with 61cm equal breakout, standard IL, no pulling eye, 3 feet
1
F
2
Z
3
T
4
R
5
P
6
8
7
N
8
Q
9
S
10
O
11
N
12
F
CHARACTER
EXAMPLE
13
0
14
0
15
3