Cut Sheet

Select Ends 1 and 2
Select Cable Options
Select Construction/Performance
Select Pulling Eye Option
Select Length
2
1
3
4
5
Pulling eye
3
Length
5
Cable
1
End 2
End 1
2
2
4
F
5 E A A
001F
5
E
X
X S P
5 = MPO female
6 = MPO male
L = LC duplex
5 = MPO female
6 = MPO male
L = LC duplex
X = 72-fibers
E = 1m breakout
2 = 2mm overjacket
(LC only)
E = 1m breakout
2 = 2mm overjacket
(LC only)
L = Low Smoke Zero
Halogen (LSZH)
P = Optical Fiber
Non-conductive
Plenum (OFNP)
S = Indoor trunk
Connector Type
End 1
Connector Type
End 2
Fiber Count
Connector Variant
Connector Variant
Jacket Type
Cable Type
9 = OS1/OS2 9/125µm
X = OM3 50/125µm
Z = OM4 50/125µm
Fiber Type
5m to 100m (005-100)
1m increments
16 ft. to 30 ft. (016-030)
1 ft. increments
M = Meters
F = Feet
Length
Unit of Length
A = Standard IL/
Polarity A
(MPO-MPO)
B = Standard IL/
Polarity B
(MPO-MPO)
X = Optimized IL/
Polarity A
(MPO-MPO)
Y = Optimized IL/
Polarity B
(MPO-MPO)
S = Standard IL/
Standard Polarity
(MPO-LC
or LC-LC)
O = Optimized IL/
Standard Polarity
(MPO-LC
or LC-LC)
A = Pulling eye End 1
Performance/
Polarity
Other
Above part number FXXSP5E5EAAF100: Fiber, OM3 50/125µm 72-fiber indoor trunk plenum cable with MPO female to
MPO female connectors with 1m breakout, Polarity A-standard IL, pulling eye on End 1, 100 ft. in length.
QuickNet
Trunk Cable Assemblies
Steps to Select:
QuickNet
Fiber Cable Assemblies – Part Numbers
Construction/
Performance
End 1 End 2CableFiber
Connector
Connector
Cable JacketCountFiber Variant
No Variant Unit
3-digit Length
Const./Perf
Other
Length
www.panduit.com
17