Installation Manual
For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2018
FS074B
Page 1 of 2
2
Key
Arc cut-outs
aligned
3
Male = Pins extracted
Pins
extracted
Gently
PanMPO Connector Changeover Instructions
(For PanMPO Connectors only)
See reverse side for Pulling Eye Removal Instructions (if applicable)
Method A
Method B
Aligned
Aligned
AlignedNot Aligned
Polarity Changeover
Squeeze both sides of outer housing at the back end evenly
until you hear an audible click.
Pull outer housing off connector.
Rotate outer housing 180° so arc cut-out is on the opposite side.
Re-install outer housing until you hear a faint audible click.
4
Key Up
Key Down
1
Squeeze
Arc cut-outs
aligned
Key
3
180°
Arc cut-out
not aligned
Arc cut-out
not aligned
Key
Gender Changeover
Remove outer housing per polarity changeover instructions. Locate hole in the inner housing on the slotted side and position
pin retraction tool over the hole.
Insert tool into hole, press down gently, and push forward to
advance connector pins to the male state. Repeat process in
opposite direction to retract pins for female state.
Re-install outer housing in the correct orientation. See polarity
changeover instructions above.
Female = Pins retracted
Pins
retracted
1
4
CAUTION! Only Panduit tool is to be
used for gender change. Use of any
other tool can cause fiber damage and
will void the product warranty.
Pin retraction
tool
hole
2
5
Aligned
Aligned
Singlemode only. The polarity of singlemode connectors must not be altered. When assembling the outer housing verify that the arc cut-
outs and white dashes align on both sides of the PanMPO housing.