MTP Cleaning Tools Model PN433 Operating Instructions

INSTALLATION INSTRUCTIONS PN433
*MTP is a registered trademark of US Conec Ltd.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4
FMTPMFCT Instructions - Cleaning Male MTP* Connectors
1. Grip the FMTPMFCT, depressing the green lever of the
cleaning tool. The metal shutter on top of the cleaning tool
will open, exposing fresh cleaning material. Fresh material
is exposed each time the green lever is depressed.
2. Position the male MTP* ferrule endface so that the fiber
tips are in contact with the cleaning material. Wipe the
ferrule endface along the cleaning material in the direction
shown on the cleaning tool.
3. Release the green lever of the cassette to cover the
cleaning material.
4. Repeat steps 1, 2 and 3 to ensure that any contamination
is removed.
NOTE: The FMTPMFCT MTP* Male Fiber Cleaning Tool is
designed to provide clearance for the connector’s guide
pins allowing the fiber tips to contact the cleaning material.
FIBCCT Instructions - Cleaning QUICKNET Cassette MTP* Connectors
1. Remove the external connector or dust cover from the
QUICKNET Cassette MTP* adapter.
2. Remove the dust cap from the FIBCCT.
3. Insert the cleaning tool tip into the MTP* adapter as
shown.
NOTE: The FIBCCT Q
UICKNET Cassette MTP* Cleaning
Tool is keyed the same as a MTP* connector. Insert the
cleaning tool tip into the Q
UICKNET MTP* adapter with the
key of the cleaning tool tip matching the keyway of the
adapter.
4. Rotate the tape feeder wheel in the direction indicated on
the cleaning tool.
5. Remove the cleaning tool from the QUICKNET Cassette
MTP* adapter.
6. Repeat steps 3, 4 and 5 to ensure that any contamination
is removed. Replace the dust cap onto the cleaning tool.
7. Clean the external connector as described in the sections
above.
8. Reinstall the external connector into the QUICKNET
Cassette MTP* adapter.