Thermal Transfer Printer OPERATOR MANUAL TDP42H, TDP43H, TDP46H

1 2 3 4 5 6 7 8
PANDUIT TDP4*HGMTDPH-MAN
Page 3-6
Section 3: Configuration
External Signal Type Selection (DSW3-6, DSW3-7). Both the polarity and signal type (level or pulse) of the
external print synchronizing signal can be selected.
Repeat Print via External Signal (DSW3-8). Allows the applicator to reprint the current label in the print buffer.
1 2 3 4 5 6 7 8
DSW1
ON
OFF
DSW3-6 DSW3-7
Off Off
Off On
SETTING
Type 4
Type 3
On Off Type 2
On On Type 1
DSW3
ON
OFF
DSW3-8 SETTING
Off Enabled
On Disabled