Energy Efficient Data Center Cabinet Systems For more information about Cisco Compatible Solutions visit https://marketplace.cisco.com/catalog and search Panduit.
Using the Panduit Energy Efficient Data Center Cabinet System, you can greatly improve the energy efficiency of your data center while confidently increasing your kW per cabinet density to increase utilization of your data center space.
Power and cooling capacity remain the top targets for efficiency improvement and optimization of cooling capacity is often the simplest way for data center operators to realize short term savings and directly impact PUE3. Panduit Labs research confirms that raising the supply air temperature in a data center is one of the most effective means to reduce energy consumption.
Complete Hot Air/Cold Air Separation is Critical to Energy Efficiency and Capacity Utilization Panduit’s Energy Efficient Data Center Cabinet System offers containment, in-cabinet ducting, and improved sealing that optimizes air separation and provide superior energy savings compared to competitive offerings. Optimized energy efficiency and capacity utilization begin with improved sealing. Even small air leaks within a cabinet will impact data center energy efficiency, regardless of the heat load.
Increase Density to Optimize Data Center Capacity Panduit Net-Access™ PDUs, integrated into thermally optimized Net-Access™ Cabinets, enable data center managers to realize higher capacity utilization and reduced OpEx and CapEx costs. Typical cabinets are loaded to 5 to 7kW on average, which is often far less than the physical space available within the cabinet resulting in overprovisioning or the need to build expensive new whitespace.
Seal, Direct, Contain, and Monitor to Improve your PUE Panduit Energy Efficient Data Center Cabinet System provides total separation allowing higher data center set points and reduced cooling system energy consumption by up to 40%.5 Seal every gap for complete separation of cooling and exhaust air Net-Access™ Cabinets and Sealing Accessories eliminate leakage through the cabinet structure preventing re-circulation of hot exhaust air back into equipment inlets.
FiberRunner ® and Wyr-Grid ®Overhead Cable Pathway Systems Net-Contain™ Vertical Exhaust Duct Sealing Accessories Net-Access™ S-Type Cabinets ™ Net-Access N-Type Cabinets Panduit® SmartZone™ Solutions Software and Hardware The Energy Efficient Data Center Cabinet System can be seamlessly integrated with all elements of the Panduit Intelligent Data Center Solution, including Overhead Cable Pathway Systems, High Speed Data Transport (HSDT) Cabling, Grounding and Bonding and Physical Infrastructure Syst
Seal Every Gap for Complete Separation of Cold Intake and Hot Exhaust Air Complete Air Seal Features Reduce Air Leakage Throughout the Cabinet Structure by as much as 25%7 Net-Access™ Cabinets have been designed to eliminate every possible air gap other than those needed to mount equipment. This minimizes by-pass air and recirculation in the cabinet providing lower inlet temperatures. Cabinet Top Seal Net-Access™ Cabinets are provided with pre-installed 1.5" x 5" or 3.
Direct Cold Air To Where It Is Needed Net-Direct™ Inlet Ducts enable optimized containment by effectively directing airflow to improve network reliability • Inlet duct solutions deliver cooling air directly from the cold aisle into the intake fans of switches • Inlet ducts are completely passive, requiring no energy to operate and eliminating a point of failure • Ensures front to back cooling airflow which enables an effective deployment of network switches with a Net-Contain™ Cold Aisle Containment deploym
Contain Cold Air or Hot Air to Maximize Cooling and Space Capacity Utilization Net-Contain™ Aisle Containment Systems Deliver Efficient Cooling for High Density Applications Data Center Managers, challenged to maximize the utilization of available rack-space and cooling capacity, often increase the power density per cabinet.
Net-Contain™ Vertical Exhaust Duct Passive Cooling for High Density Applications Net-Contain™ Vertical Exhaust Duct (VED) Systems optimize cooling energy utilization to support high density heat loads to enable 30kw or greater per cabinet.
Monitor to Maintain Operational and Energy Efficiency Data center managers are challenged to maintain and manage energy efficiency gains in a highly dynamic, virtualized environment in which power consumption, environmental and capacity utilization variables are constantly changing.
Power Distribution Units (PDUs) Power and Environmental Hardware As power densities increase, monitoring of power and environmental information using an intelligent power distribution unit (PDU) is critical to preventing power overload and downtime. Panduit supports power and environmental management through two distinct intelligent PDU families: PViQ™ PDUs connect directly to the network and SmartZone™ PDUs which connect via a gateway.
Net-Access™ N-Type Cabinets Optimum Accessibility and Cable Management for High Density Applications Net-Access™ N-Type Cabinets are the first choice for data center managers and systems integrators specifying high density network, storage and compute applications that require optimal thermal management and the capacity to manage high cable densities.
Open rail mounting creates more cable management space and equipment positioning flexibility High strength frame eliminates need for support members between rails, providing unobstructed space between the frame and the side panels. Vertical split side panels enable fast access to equipment Innovative vertical split side panels and optional vertical split hinged side panels allow fast easy access to end of row network equipment and cabling, eliminating time consuming handling.
Net-Access™ S-Type Cabinets Cost Effective and Versatile Cabinets for all Data Center Applications and Facilities Designs Net-Access™ S-Type Cabinets provide data center managers and systems integrators an unprecedented range of features in a cost effective cabinet platform for server, network, and pre-configured cabinet applications.
Out-Set Cable Entry Improves Floor Space Utilization by 5% Network cable entry locations are outside of equipment area, allowing top 2 RUs to be used, optimizing cabinet utilization and saving floor space.
Simplify and Accelerate Data Center Deployments Net-Access™ Cabinets Enable Pre-Configuration of Network Equipment Pre-Configured Solutions Add Value and Reduce Installation Time and Cost Dynamic rated Net-Access™ N-Type and S-Type Cabinets allow pre-installation of IT equipment for faster deployments and time to production. Panduit Pre-Configured Solutions are fully tested and validated physical infrastructures that ensure best practice installations and optimal system performance.
Net-Access™ Cabinet and Thermal Management Solution for Cisco^ Nexus 7018 Switch Panduit offers a Net-Access™ Cabinet solution designed to meet the thermal and operating requirements of the modular, high density Cisco^ Nexus 7018 Switch. Based on a standard 800mm (31.5") wide Net-Access™ N-Type Cabinet, an easy to use expansion module provides space to route and manage high densities of cables. Internal ducting enables front to back cooling air flow and improved reliability.
Net-Access™ Integral Cabinet Top Cable Routing System Speed deployments and optimize overhead space utilization Net-Access™ Cabinets are available with an Integral Cabinet Top Cable Routing System that protects, routes, and manages large quantities of twisted pair data cables into and out of any Net-Access™ Cabinet.
Net-Access™ N-Type Cabinet Specifications • Welded and assembled steel frame construction • Easy maintenance powder coat finish • Adjustable rear equipment rails with continuous positioning • Large cable entry/cable access • Doors include keyed swing handles • Side panels • Dual hinge door for maximum accessibility between adjacent cabinets • Cabinet supplied with 2 sets of high density cable management fingers (SN25F) • Cable entry holes are equipped with plastic sealing plugs • UL 2416 standard compliant
Net-Access™ N-Type and S-Type Cabinet Offering and Availability Overview Multiple cabinet solutions to meet your project goals – from standard cabinets for quick turnaround to customer configured cabinet for specific deployments, Net-Access™ N-Type and S-Type Cabinets provide a complete solution to meet customer requirements.
Net-Access™ N-Type Standard Configured Cabinets Series Width Height Depth Side Panels Color N 8 = 800mm 2 = 42 RU 1 = 1070mm 2 = 2 Side Panels* B = Black C = Cage Nut Rails Standard Options (Select Only One) 5 = 45 RU 2 = 1200mm 9 = No Side Panel W = White E = Single Hinge Front Door and Cage Nut Rails S = No Doors** 8 = 48 RU T = Integral Cabinet Top Cable Routing System** TC = Integral Cabinet Top Cable Routing System and Cage Nut Rails U = Vertical Blanking and Cage Nut Rails V = VED
Net-Access™ N-Type and S-Type Cabinets with Integral Cabinet Top Cable Routing System N-Type Width S-Type Width 800mm 800mm 700mm 600mm 42 RU N8212BT S8212BT S7212BT S6212BT 45 RU N8512BT S8512BT S7512BT S6512BT 48 RU N8812BT S8812BT S7812BT S6812BT 42 RU N8222BT S8222BT S7222BT S6222BT 45 RU N8522BT S8522BT S7522BT S6522BT 48 RU N8822BT S8822BT S7822BT S6822BT 42 RU N8219BT S8219BT S7219BT S6219BT 45 RU N8519BT S8519BT S7519BT S6519BT 48 RU N8819BT S8819BT S
Net-Access™ N-Type and S-Type Vertical Exhaust Duct (VED) Cabinets (VED Sold Separately) N-Type Width With Side Panels Without Side Panels S-Type Width 800mm 800mm 700mm 600mm 42 RU N8222BV S8222BV S7222BV S6222BV 45 RU N8522BV S8522BV S7522BV S6522BV 48 RU N8822BV S8822BV S7822BV S6822BV 42 RU N8229BV S8229BV S7229BV S6229BV 45 RU N8529BV S8529BV S7529BV S6529BV 48 RU N8829BV S8829BV S7829BV S6829BV 1200mm depth 1200mm depth * VED cabinets only available in 1200mm de
Net-Contain™ Cold and Hot Aisle Containment Part Number Description Net-Contain™ Aisle Containment Sliding Doors C2CACT5F**SD^^ Net-Contain™ Sliding Door CAC for **ft (**mm) aisle- capable of 42 up to 45 RU – ^^ colored. ** = 04 = 4ft (1200mm), 06 = 6ft (1800mm) ^^ = B1 = Black, W1 = White. Net-Contain™ Integral Low Profile Ceiling Structure for Net-Access™ N-Type and S-Type Cabinets C2CAC08F**IR^^ Net-Contain™ (CAC) Integral Roof for 800mm width cabinet with **ft (**mm) aisle width – ^^ colored.
Net-Contain™ Universal Aisle Containment System Part Number CUEFRT8F**ST CUEFRT9F**ST Description Net-Contain™ End of Row Frame for Roofing CUEFRT8F**ST^^ Net-Contain™ UAC End of Row Frame for Roofing - 42/45 RU high. CUEFRT9F**ST^^ Net-Contain™ UAC End of Row Frame for Roofing - 48/52 RU high. ** 04 = 4' (1200mm) aisle width, 06 = 6' (1800mm aisle width) ^^ = B1 = Black, W1 = White. Net-Contain™ Mid-Span Post CUSMPR52ST01B1 CUSMPR52ST01B1 Net- Contain™ Mid-Span Post 42 RU to 52 RU high.
Net-Access™ Cabinet Accessories Part Number N-Type S-Type Compatible Compatible Description POU Brackets and Cable Management SN15F SN25F SN15F x x Finger Kit, 100mm (3.9") depth that attaches to posts on 42 RU through 48 RU cabinets. SN25F x x Finger Kit, 150mm (5.9") depth that attaches to posts on 42 RU through 48 RU cabinets. x Vertical patching bracket for 700mm wide cabinets. x Vertical patching bracket for 800mm wide cabinets.
Net-Access™ Cabinet Accessories (continued) Part Number N-Type S-Type Compatible Compatible Description Vertical Blanking Panels NVBP NVBP x Vertical blanking panels with pass-through holes for 42 RU through 48 RU cabinets. S6VBPN x* Vertical blanking panel for 600mm cabinets. S7VBPN x* Vertical blanking panel for 700mm cabinets. S8VBPN x* Vertical blanking panel for 800mm cabinets with 25mm (1") x 127mm (5") knock-outs.
Net-Access™ Cabinet Accessories (continued) Part Number N-Type S-Type Compatible Compatible Description Side Panels N**SPS N**SPH N21SPS x Split side panel set for 42 RU 1070mm depth cabinet. N51SPS x Split side panel set for 45 RU 1070mm depth cabinet. N81SPS x Split side panel set for 48 RU 1070mm depth cabinet. N22SPS x Split side panel set for 42 RU 1200mm depth cabinet. N52SPS x Split side panel set for 45 RU 1200mm depth cabinet.
Net-Access™ Cabinet Accessories (continued) Part Number N-Type S-Type Compatible Compatible Description Integral Cabinet Top Cable Routing System SN7TCDW SN8TCDW SN8TCDW x SN7TCDW SN1070CREC SN1200CREC SN1200VCREC x Divider wall with screws for integral cabinet top cable routing system to enhance cable management. For 800mm wide cabinet. x Divider wall with screws for integral cabinet top cable routing system to enhance cable management. For 600mm and 700 mm wide cabinets.
Net-Direct™ In-Cabinet Ducting CDE1 Part Number Description Inlet Ducts CDE1 Net-Direct™ Air Inlet Duct, 1 RU that resides below the switch provides cold aisle airflow to Cisco^ 4948, 4928, and 4924. Optimized for use in server cabinet applications. CDE2 Net-Direct™ Air Inlet Duct, 1 RU that resides in-line and below switch provides cold aisle airflow to Cisco^ Nexus N2K-C2148T-1GE, N2K-C2248TP-1GE, and N2K-C2232PP-10GE fabric extenders and Cisco^ WS-C4948E-F, WS-C4948E-F-S, and WS-C4948E-F-E.
Net-Direct™ In-Cabinet 7018 Ducting and 7018 Accessories Part Number Description 7018 Ducting Solution DIEBCC7018B DIRLD0425S27W DIEBCC7018B Net-Direct™ Air Inlet and Exhaust Ducting (blanking panels not included) designed for Cisco^ Nexus 7018 switch in a 1000mm wide Net-Access™ N-Type Cabinet. DIRLD0425S27W Net-Direct™ Air Inlet Ducting with left and right side blanking panels for 42/48 RU cabinet designed for Cisco^ Nexus 7018 switch in a 1000mm wide Net-Access™ N-Type Cabinet .
Power Outlet Units (POUs) North America Part Number Description Vertical Metered POUs VB1A1M2BM30P1 VB1A1M2BM30P1* 30A, Single Phase, L5-30P Plug, 120V, (24) C-13/(6) C-19 Receptacles. VB1B1L2BN30P1* 30A, Single Phase, L6-30P Plug, 208V, (24) C-13/(6) C-19 Receptacles. VB1B1J0BA30P1* 20A, 3 Phase WYE, L21-20P Plug, 208V, (24) C-13/(6) C-19 Receptacles. VB1B1P3BN30P1* 30A, 3 Phase WYE, L21-30P Plug, 208V, (24) C-13/(6) C-19 Receptacles.
Power Outlet Units (POUs) Global Part Number Description Vertical Metered POUs VB1D2B2BM30P1 VB1D2A0BA30P1* 16A, Single Phase, IEC 60309 - 6H 2P+E Blue Splashproof Plug, 230V, (24) C-13/(6) C-19 Receptacles. VB1D2B2BM30P1* 32A, Single Phase, IEC 60309 - 6H 2P+E Blue Splashproof Plug, 230V, (24) C-13/(6) C-19 Receptacles. VB1D2P3BN30P1* 32A, 3 Phase WYE, IEC 60309 - 6H 3P+N+E Red Splashproof Plug, 230/400V, (24) C-13/(6) C-19 Receptacles.
Blanking Panels and Blanking Shade Part Number TLBP1 TLBP2 Description Tool-Less Blanking Panels TLBP1S-V 19" (483mm) width for 3/8" cage nut holes (may be used with or without cage nuts installed). 1 RU. TLBP2S-V 19" (483mm) width for 3/8" cage nut holes (may be used with or without cage nuts installed). 2 RU. TLBP1R-V 19" (483mm) width for tapped rails. 1 RU. TLBP2R-V 19" (483mm) width for tapped rails. 2 RU.
Sealing Accessories Part Number CTGN1X5 Description Cool Boot ® Cabinet Top Air Sealing Fitting CTGN1X5 Used to seal off 1" x 5" cabinet top openings when cables are routed through the top of a cabinet. Airtight fabric and Ultra-Cinch™ Tie close top of fabric, minimizing hot air bypass around cables to improve cooling of network equipment and reduce energy costs. For use with 600mm wide Net-Access™ Cabinets.
Telecommunications Grounding Accessories CNBK Std. Pkg. Qty. 1 Part Number CNBK Description Green bonding cage nut, includes 50 #12-24 bonding cage nuts (.06 – .11 thick panel) and 50 #12-24 x 1/2" bonding screws with #2 Phillips/slotted combo hex head (use 5/16" or 8mm socket). RGCBNJ660P22 Mesh common bonding network (MCBN) jumper kit; #6 AWG (16mm2); 60" (1.52m) length; 45° bent lug on grounding strip stide; provided with .16oz.
Energy Efficient Data Center Cabinet System A Part of Panduit’s Intelligent Data Center Solution Panduit’s Unified Physical InfrastructureSM (UPI)-based Intelligent Data Center Solutions embody the next wave of systems integration and risk management by aligning and harmonizing critical systems to support the delivery of secure, energy-efficient, always-on, real-time data and services.
Real-World Solutions With a proven reputation for excellence and innovation, Panduit and our partners work with you to overcome challenges and implement real-world solutions that create a competitive business advantage. Panduit offers the broadest range of solutions, from data centers and intelligent buildings to manufacturing operations, to help you build a smarter, unified business foundation.