Table 2 - Summary of total 28 AWG patch cord length vs. maximum channel length.
Total 28 AWG Patch Cord
Length
Maximum 23 AWG Horizontal
Cable Length
Maximum Total Channel Length
Meters
Feet
Meters
Feet
Meters
Feet
2
7
98* 321
100
328
3
10 96* 314 99 324
4
13 94* 308 98 321
5
16 92* 301 97 317
6
20
90
295 96 315
7
23 88.5 290 95.5 313
8
26 86.5 283 94.5 309
9
30 84.5 277 93.5 307
10
33 83 272 93 305
11 36 81 265 92 301
12 39 79 259 91 298
13 43 77 252 90 295
14 46 75 246 89 292
15 49 73.5 241 88.5 290
16 52 71.5 234 87.5 286
17 56 69.5 228 86.5 284
18 59 67.5 221 85.5 280
19 62 65.5 214 84.5 276
20 66 64 209 84 275
* Horizontal cable lengths over 90 meters will not pass Permanent Link testing with a field tester, however the
total channel will pass Channel testing and Ethernet traffic.
Note: Beyond 20 meters the maximum length of 28 AWG patch cords may be limited by DC Loop Resistance
specifications. Panduit’s 28 AWG Category 6A performance patch cords are limited to a maximum length of 40
meters in point-to-point applications (using only patch, with no horizontal cable).