User Manual

Table Of Contents
72681-9-2-2015
Mounting Instructions
Save these instructions
Page 4
11.40”
(28.9 cm)
Drill 1/4”
(6.5mm) hole
Drywall Anchor
Anchors are for dry-
wall where wall studs
are unavailable
1 1/4” screw
Fig. 1
Fig. 2
Fig. 3
Assembly View
Dowel
Base Mount
Frame
Paraclipse Fly Patrol
Contents:

Operation Manual
 One Sconce Assembly
 Drywall Anchor kit with Instructions
 One Frame Assembly with Power Cord
 One Cartridge
 One UV Quantum Lamp
Unit location on wall - Fig. 1
Select a wall away from windows or competing
light source. For best results, mounting holes
should be located 66” (1.68 m) above the floor.
Mounting unit to wall - Fig. 2
1. Mark two locations on the wall for your fasten-
ers that are 11.4” (28.9cm) apart. Make sure
that the marks are level with each other.
Types of Fasteners that can be used:
Drywall anchors
NOTE: When using the drywall anchors
follow the instructions provided in the
Wall Anchor Kit.
Two Screws
Combination of one anchor and one
screw
NOTE: The wall anchor kit provided will
accommodate these combinations.
2. Use a Phillips head screwdriver to mount the
frame assembly on the wall. The frame as-
sembly must be securely mounted to the wall.
NOTE: For other surfaces, such as concrete,
different fasteners or anchors maybe re-
quired. These types of fasteners are not in-
cluded.
Base Mounted - Fig. 3
You may wall mount as a sconce or place on
provided base mount as shown in Fig.3 Make
sure frame is placed securely on both dowels
and base mount is secure.
Use caution in placement of unit as to avoid
unit from being knocked over. Make sure cord is
placed where it will not get caught or tripped on.
Locate mounting holes
approximately 66” (1.68m)
above floor
72681-9-2-2015
Paraclipse Fruit Fly Patrol™
Page 5
Ultraviolet Lamp/Cartridge Installation
Frame
Assembly
Lamp Socket
Fig. 4
Fig. 5
Fig. 6
Ultraviolet Lamp
Drive Spool
Cartridge
Motor Enclosure
Alarm Hole
Lamp and Cartridge Installation:
Note: Unit must be securely mounted to wall
or placed on base mount before you proceed
with the installation of Lamp & Cartridge
1.
Remove the ultraviolet lamp from the box.
Insert the lamp into the lamp socket by align-
ing the pins of the lamp with the light socket
and snap in firmly. (Fig. 4 & 5) NOTE: It is
recommended to replace the ultraviolet lamp
every eight months of use to maintain
optimum performance of the unit. After this
time the lamp may still light but is no longer
emitting enough of the special UV light
frequency required for an effective insect
catch.
2. Rotate the drive spool of the cartridge in the
direction of the arrow shown on the drive spool
until the tacky paper is across the cartridge.
(Fig. 5)
3. Position the cartridge on the top of the motor
enclosure. Push the cartridge in until it stops.
(Fig. 5 & 6) NOTE: About 6 to 7 rotations will
be required.
Replacement Quantum Lamp Kit: part # 72480
Cartridge Alarm:
The Paraclipse Fly Patrol has an out of paper
sensor that emits an audible beep when it is time to
replace the cartridge. The alarm is triggered when
the paper no longer covers the alarm hole in the top
of the motor enclosure. ( see Fig. 4)
To test the operation of the alarm follow these steps.
1. Plug the unit into the outlet
2. Carefully remove the cartridge. The alarm
should emit an audible beep.
3. Stop the alarm by installing a fresh cartridge.