- Paradox Keypad User Guide
 EVO Systems 9
5.8 Auto-Arming
If enabled by your installer, you can set the time that an area will arm itself automatically.
5.8.1 Timed Auto-Arming
Your installer can set Timed Auto-Arming to function in either Force or Stay arming 
mode. A sixty-second (default value) Exit Delay sequence will begin prior to your 
system automatically arming itself at the programmed time. 
To set the Auto-Arming timer:
1. Enter your [
ACCESS CODE]. 
2. Press the [0] button.
3. Press the [
MEM] button. 
4. If you have access to more than one area, press the area’s
 number, or use the 
[S] and [T] buttons and press the [
ACC] button when the area you want to 
program appears on the screen. 
5. Enter the time you want the area to be armed according to the 24-hour clock 
(i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).
6. Press the [
ENTER] button to save and exit. 
If you are using the DGP2-648BL LED keypad, The 
MEM action light will 
flash if a time is not already programmed. The 
PRG action light, the area 
light of the chosen area, and the first number of the previous time set will 
illuminate (
10 light = zero).
5.8.2  No Movement Auto-Arming
Your system can be programmed to send a report to your monitoring station and/
or arm the system if there is no activity in the area during a specified period of 
time. Your installer can set No Movement Auto-Arming to function in either 
Regular or Stay arming mode.
LCD LED