Spectra 1759MG 11
4.4.2 Partition 2 Assignment
Sections [302] to [348]: User Codes 002 to 048
Option [2] OFF = Deny access to partition 2 (default)
Option [2] ON = User code has access to partition 2
If the system is partitioned (see Partitioning on page 36), user codes with this option enabled can arm and disarm
partition 2. If the system is not partitioned, the control panel ignores this option.
4.4.3 Bypass Programming
Sections [302] to [348]: User Codes 002 to 048
Option [3] OFF = Bypass Programming Disabled
Option
[3]
ON = Bypass Programming Enabled (default)
User codes with this option enabled can perform Bypass Programming in assigned partitions.
4.4.4 Stay Arming
Sections [302] to [348]: User Codes 002 to 048
Option [4] OFF = Stay Arming Disabled
Option [4] ON = Stay Arming Enabled for selected User Code (default)
User codes with this option enabled can Stay arm assigned partitions.
4.4.5 Force Arming
Sections [302] to [348]: User Codes 002 to 048
Option [5] OFF = Force Arming Disabled (default)
Option [5] ON = Force Arming Enabled for selected User Code
User codes with this option enabled can Force arm assigned partitions.
4.4.6 Arm Only
Sections [302] to [348]: User Codes 002 to 048
Option [6] OFF = Arm Only Disabled (default)
Option [6] ON = Arm Only Enabled for selected User Code
The user code with this option enabled can arm assigned partitions, but cannot disarm any partitions. The type of
arming is dependent on the other User Code Options selected. Please note that with the Arm Only option, the user can
cancel a recently armed system by re-entering the access code before the end of the exit delay.
4.4.7 PGM Activation
Sections [302] to [348]: User Codes 002 to 048
Option
[7]
OFF = User Code follows User Code Options and can activate a PGM (default)
Option [7] ON = User Code can activate a PGM only
With option [7] off, entering the access code will arm or disarm according to the programmed User Code Options as
well as activate or deactivate a PGM. The appropriate PGM Activation/Deactivation Event must also be programmed
(see Programmable Outputs on page 34). With option [7] on, the control panel will ignore all other User Code Options.
Therefore, entering the access code will only activate or deactivate the PGM.
4.5 Lock Master Code
Section [127]: System Options
Option [4] OFF = Lock System Master Code Disabled (default)
Option [4] ON = Lock System Master Code Enabled
With this feature enabled, the control panel will lock the System Master Code (001). This means that the System Master Code
cannot be deleted, but it can be changed.
4.6 Duress Code
Section [127] = System Options
Option [6] OFF = Duress Code Disabled (default)
Option [6] ON = User Code 048 becomes a Duress code
With this feature enabled, User Code 048 becomes a Duress Code. When forced to arm or disarm their system, users can enter
a Duress Code (User Code 048) to arm or disarm the system which can immediately transmit a silent alert to the monitoring
station, transmitting the duress report code programmed in section [196].