Installation Instructions
Table Of Contents
- Part 1: Introduction
- Part 2: Installation
- Part 3: Programming Methods
- Part 4: Access Codes
- Part 5: Zone Programming
- Part 6: Wireless Features
- Part 7: Arming and Disarming Options
- 7.1 Switch To Stay Arming
- 7.2 Stay Arming with Delay
- 7.3 Regular Arming Switches to Force Arming (Not to be used with UL Installations)
- 7.4 Restrict Arming on Battery Fail
- 7.5 Restrict Arming on Tamper Failure
- 7.6 Timed Auto-Arming
- 7.7 No Movement Auto-Arming
- 7.8 Auto-Arming Options (Not to be used with UL installations)
- 7.9 One-Touch Arming (Not to be used with UL installations)
- 7.10 Exit Delay
- 7.11 Bell Squawk On Arm/Disarm with Keypad
- 7.12 Bell Squawk On Arm/Disarm with Remote Control
- 7.13 No Exit Delay When Arming with Remote Control
- 7.14 No Exit Delay Beeps and No Bell Squawk When Stay Arming
- Part 8: Alarm Options
- Part 9: Reporting and Dialer settings
- 9.1 Reporting/Dialer (Enable/Disable)
- 9.2 Report Codes
- 9.2.1 Arming Report Codes
- 9.2.2 Special Arming Report Codes
- 9.2.3 Disarming Report Codes
- 9.2.4 Special Disarming Report Codes
- 9.2.5 Zone Alarm Report Codes
- 9.2.6 Zone Alarm Restore Report Codes
- 9.2.7 Special Alarm Report Codes
- 9.2.8 Zone Tamper Report Codes
- 9.2.9 Zone Tamper Restore Report Codes
- 9.2.10 System Trouble Report Codes
- 9.2.11 System Trouble Restore Codes
- 9.2.12 Special Reporting Codes
- 9.3 Monitoring Station Telephone Numbers
- 9.4 Partition Account Numbers
- 9.5 Reporting Formats
- 9.6 Pager Delay
- 9.7 Event Call Direction
- 9.8 Dialing Method
- 9.9 Pulse Ratio
- 9.10 Bell on Communication Failure
- 9.11 Dial Tone Delay
- 9.12 Maximum Dialing Attempts
- 9.13 Delay Between Dialing Attempts
- 9.14 Alternate Dial Option
- 9.15 Recent Close Delay
- 9.16 Auto Test Report
- 9.17 Closing Delinquency Timer
- 9.18 Power Failure Report Delay
- 9.19 Disarm Reporting Options
- 9.20 Zone Restore Report Options
- 9.21 Telephone Line Monitoring (TLM)
- Part 10: Programmable Outputs
- Part 11: System Settings
- 11.1 Hardware Reset
- 11.2 Installer Lock
- 11.3 Keypad Lockout Feature
- 11.4 Battery Charge Current
- 11.5 Partitioning
- 11.6 System Real-Time Clock
- 11.7 Clock Adjust
- 11.8 Keypad Tamper Supervision
- 11.9 Keypad Audible Trouble Warning
- 11.10 Confidential Mode
- 11.11 Installer Quick Functions Keys
- 11.12 PGM Modules Supervision
- 11.13 Printer Module Supervision
- 11.14 Zone Expansion Bus Module Supervision
- 11.15 Wireless Transmitter Low Battery Supervision
- 11.16 Wireless Transmitter Supervision Options
- 11.17 Reprogram All Expansion Modules
- Part 12: Settings for WinLoad Software
- Part 13: User Operation
- 13.1 Trouble Display
- 13.2 Programming Access Codes
- 13.3 Disarming & Deactivating an Alarm
- 13.4 Regular Arming
- 13.5 Stay Arming
- 13.6 Instant Arming
- 13.7 Force Arming (Not to be used with UL Installations)
- 13.8 Manual Bypass Programming
- 13.9 One-Touch Arming
- 13.10 Keyswitch Arming
- 13.11 Panic Alarms
- 13.12 Auto-Arming (Not to be used with UL installations)
- 13.13 Alarm Memory Display
- 13.14 Programming Chime Zones
- 13.15 Keypad Muting (Not to be used with UL installations)
- 13.16 Keypad Backlight (1686H and 1686V only)
- FCC Warnings
- Index
12 Reference & Installation Manual
Part 5: Zone Programming
When programming zones, the zone assignments are dependent on where the detection devices are connected to in the system (see Table
4). In installations that require using mostly the expansion inputs (see section 5.1), refer to Reassign Keypad Zone 2 on page 12 and
Reassign Zones to Expansion Inputs on page 13.
Table 4: Zone Recognition Table
5.1 What is an Expansion Input?
An expansion input allows you to connect modules to the system to increase the number of zones available up to 15 zones. Each
hardwired input on a zone expansion bus module or wireless transmitter can be assigned to an expansion input. The expansion
inputs can be used in any combination. For example, 5 wireless transmitters and 3 hardwire inputs can be assigned to the
expansion inputs. Spectra control panels cannot support more than eight expansion inputs. Refer to the appropriate module’s
Instruction Sheet for details.
Do not assign inputs from different modules to the same expansion input.
5.2 Reassign Keypad Zone 2
Section [126]: General Options
Option [7] OFF = Reassign Keypad Zone 2 Disabled (default)
Option [7] ON = Reassign Keypad Zone 2 Enabled
In installations that require using mostly the expansion inputs, such as using wireless zones, 10-Zone LED keypads may be
unable to display some of the zones. The Reassign Keypad Zone 2 feature changes the zone numbering to increase the number
of expansion inputs that are displayed on 10-Zone LED keypads. Combine with the Reassign Zones to Expansion Inputs feature
(see page 13) to increase the number of displayable expansion inputs. See Table 4 for Zone Recognition.
When Reassign Keypad Zone 2 is enabled, the Keypad Tamper Supervision (see page 37) for Keypad Zone 2 is
lost. Keypad Tamper Supervision will
ONLY function on Keypad Zone 1.
Option [7]: OFF
Option [8]: OFF
Option [7]: ON
Option [8]: OFF
Option [7]: OFF
Option [8]: ON
Option [7]: ON
Option [8]: ON
Control Panel
Input 1 =
Zone 1 Zone 1 Zone 1 Zone 1
Input 2 =
Zone 2 Zone 2 Zone 2 Zone 2
Input 3 =
Zone 3Zone 3N/A N/A
Input 4 =
Zone 4Zone 4N/A N/A
Input 5 =
Zone 5Zone 5N/A N/A
Keypad
Zone 1 =
Zone 6 Zone 6 Zone 3 Zone 3
Zone 2 =
Zone 7 N/A Zone 4 N/A
Expansion
Input 1 =
Zone 8 Zone 7 Zone 5 Zone 4
Input 2 =
Zone 9 Zone 8 Zone 6 Zone 5
Input 3 =
Zone 10 Zone 9 Zone 7 Zone 6
Input 4 =
Zone 11 Zone10 Zone 8 Zone 7
Input 5 =
Zone 12 Zone 11 Zone 9 Zone 8
Input 6 =
Zone 13 Zone 12 Zone 10 Zone 9
Input 7 =
Zone 14 Zone 13 Zone 11 Zone 10
Input 8 =
Zone 15 Zone 14 Zone 12 Zone 11
= not displayed on 10-Zone LED Keypads
Option [7] = Reassign Keypad Zone 2
Option [8] = Reassign Zones to Expansion Inputs