Installation Instructions

Table Of Contents
22 Reference & Installation Manual
* Event Group #07, #08 and #09 (Button Pressed on Remote) of the Spectra 1759MG PGM Table. For the PGM Table, please refer to the
Spectra 1759MG Programming Guide (1759MG-EP).
† The Panic feature must be enabled in the control panel.
Part 7: Arming and Disarming Options
7.1 Switch To Stay Arming
Section [133]: Partition 1, Section [134] = Partition 2
Option [4] OFF = Switch to Stay Arming Disabled (default)
Option [4] ON = Switch to Stay Arming Enabled
If a user Regular arms a partition, but does not exit through (open and close) an entry delay zone during the exit delay, the control
panel can be programmed to switch from Regular arming to Stay arming.
7.2 Stay Arming with Delay
Section [133]: Partition 1, Section [134] = Partition 2
Option [5] OFF = Stay Arming with Delay Disabled (default)
Option [5] ON = Stay Arming with Delay Enabled
If a partition is Stay armed when this feature is enabled, all the zones in the partition, except 24Hr zones and Stay zones, are
associated with the Stay Delay. Therefore, the control panel will not generate an alarm if a zone is breached until the Stay Delay
has elapsed. This feature prevents false alarms by allowing users enough time to disarm their system if a zone is accidentally
triggered. For example, if a user opens an armed window or crosses an armed detector on the way to the kitchen in the middle of
the night, the user will have enough time to disarm the system before the alarm is generated. Each partition’s Stay Delay follows
the value programmed in Entry Delay Timer 2 in section [070].
Table 7: Button Options
[FORCE] = Button Disabled [7] = Regular Arm and Disarm
[1] = Regular Arm [8] = Generate a Panic 1† Alarm (Police)
[2] = Stay Arm [9] = Generate a Panic 2† Alarm (Medical)
[3] = Instant Arm [A] = Generate a Panic 3† Alarm (Fire)
[4] = Force Arm [B] = Activates any PGMs that have Event Group #07* as their Activation Event
[5] = Disarm [C] = Activates any PGMs that have Event Group #08* as their Activation Event
[6] = Disarm when there is no alarm [D] = Activates any PGMs that have Event Group #09* as their Activation Event
Figure 13: Remote Control Button Identification
Four button Remote Control