Spectra 1759MG 33
9.12 Maximum Dialing Attempts
Section [081]
001 to 016 attempts, Default = 8 attempts
The value programmed in section [081] determines how many times the control panel will re-dial the same monitoring station
telephone number before proceeding to the next number.
9.13 Delay Between Dialing Attempts
Section [082]
000 to 255 seconds, Default = 20 seconds
This delay determines the amount of time the control panel will wait between each dialing attempt.
9.14 Alternate Dial Option
Section [136]: Dialer Options
Option [4] OFF = Alternate Dial Disabled (default)
Option [4] ON = Alternate Dial Enabled
With option [4] OFF, the control panel will dial the backup telephone number programmed in section [153] after all attempts to
one monitoring station telephone number have failed (see Maximum Dialing Attempts on page 33). With option [4] ON, the
control panel will dial the backup telephone number after every failed attempt.
9.15 Recent Close Delay
Section [085]
000 to 255 seconds, Default = no delay
If after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the control panel will
attempt to transmit the Recent Close report code programmed in section [195].
9.16 Auto Test Report
Sections [087]
000 = Disabled, 001 to 255 days, Default = Disabled
Section [110]: Time (HH:MM)
The control panel will transmit the Test Report report code programmed into section [211] after the number of days programmed
into section [087] has elapsed at the time programmed into section [110]. Use the 24-hour clock to program the time (i.e. 6:30PM
= 18:30). The first Test Report will be transmitted within 24 hours after the feature is enabled at the time programmed in [110].
Example: Section [087] = 005 and section [110] = 13:00. The first Test Report will be sent at 1 PM that day and then the report
will be sent every 5 days at 1 PM.
9.17 Closing Delinquency Timer
Section [095]
000 = Disabled, 001 to 255 days, Default = Disabled
At midnight every day, the control panel will verify when the partition was last disarmed. If the partition has not been armed within
the time programmed in the Closing Delinquency Timer, the control panel will transmit a Closing Delinquency event to the
monitoring station.
Example: The Closing Delinquency Timer for partition 1 in section [095] is programmed for 005 days. Spectra verifies when
partition 1 was last disarmed at midnight every day. If partition 1 was not armed within the last 5 days, Spectra will transmit a
Closing Delinquency event to the monitoring station.
The Closing Delinquency Event and timer apply only to partition 1.
9.18 Power Failure Report Delay
Section [086]
001 to 255 minutes, Default = 15 minutes
The control panel will transmit the AC Failure report code programmed in section [205] after the Power Failure Report Delay
period has elapsed.
9.19 Disarm Reporting Options
Section [131]: Arming /Disarming Options
Option [1] OFF = Always Report Disarming
Option [1] ON = Report Disarming Only After Alarm (default)