Installation Instructions

Table Of Contents
Spectra 1759MG 45
13.8.1 Bypass Recall Feature
After disarming the system, the control panel will erase the bypass entries. By using the Bypass Recall Feature, you
can reinstate the previous bypass entries saved in memory. This eliminates the need to manually program the bypass
entries every time you arm the system. The access code must have the Bypass Programming Option enabled.
13.9 One-Touch Arming
One-touch arming allows users to arm the system without using an access code. Simply press and hold a key. One-touch arming
can be used to allow specific individuals like service personnel (i.e. cleaners, maintenance) to arm the system when leaving the
protected area, without giving them access to any other alarm system operations.
One-Touch Regular Arming: Press and hold the [
ENTER] key for 3 seconds* to arm all zones in the partition.
One-Touch Force Arming: Press and hold the [
FORCE] key for 3 seconds* to bypass any open Force Zones.
One-Touch Bypass Programming: Press and hold the [
BYP] key for 3 seconds* to access Bypass Programming Mode.
One-Touch Stay Arming: Press and hold the [
STAY] key for 3 seconds* to arm all zones not defined as Stay Zones.
Fast Exit - When the system is already Stay armed:
To Exit and Stay Arm: Press and hold the [
STAY] key for 3 seconds*. The system will switch to exit delay. At the end of the exit
delay period, the system will return to Stay arming.
To Exit and Regular Arm: Press and hold the [
ENTER] key for 3 seconds*. The system will switch to exit delay. At the end of the
exit delay period, the control panel will switch to Regular arming.
To Exit and Force Arm: Press and hold the [
FORCE] key for 3 seconds*. The system will switch to exit delay. At the end of the
exit delay period, the control panel will switch to Force arming.
13.10 Keyswitch Arming
A keyswitch can be used to arm and disarm the system. Assign the keyswitch to a specific partition and program the keyswitch to
Stay or Regular arm the assigned partition. Also program the keyswitch to function as a Maintained or Momentary keyswitch. To
arm the system using a Maintained Keyswitch, set the keyswitch to the
ON position. To disarm the system set the keyswitch to the
OFF position. To arm the system using a Momentary Keyswitch, set the keyswitch to the ON position then turn it back to the OFF
position. Repeating this sequence will disarm the system.
13.11 Panic Alarms
In case of emergency, the Spectra system provides up to three panic alarms. These panic alarms, if programmed, will immediately
generate an alarm after pressing and holding two specific keys for two seconds, as described below.
Press and hold keys [1] and [3] for a panic alarm.
Press and hold keys [4] and [6] for a panic or medical alarm.
Press and hold keys [7] and [9] for a panic or fire alarm.
13.12 Auto-Arming (Not to be used with UL installations)
Each partition can be programmed to arm every day at the time specified by the Auto-arm Timer or for the period specified by the
No Movement Timer. The user can program the Auto-arm Timer by using the System Master Code, Master Code 1 or Master
How do I Program Bypass Entries?
1) Press the [BYP] key.
2) Key in a valid [ACCESS CODE]*.
3) Select one or more [ZONES] you wish to bypass.
4) Once you have entered the desired bypass entries, press the [
ENTER] key to accept these entries.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the desired partition.
How Do I Recall Bypass Entries?
1) Press the [BYP] key.
2) Key in your [
ACCESS CODE]*.
3) Press the [
BYP] key. Previously bypassed zones will illuminate.
4) Press the [ENTER] key.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the desired partition.
* If you have access to both partitions after activating a one-touch feature, press the key corresponding to the desired partition.
To select both partitions, press the [1] key then after the confirmation beep press the [2] key.