Programming Guide

Spectra 1759MG - 10 - Programming Guide
09 = Button Pressed on Remote
(see button option ā€œDā€ on page 25)
01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control
10 = Bypass Programming 01 to 48 = User Code Numbers 001 to 048
99 = Any User Code
11 = User Activated PGM 01 to 48 = User Code Numbers 001 to 048 (Partition 1 only)
99 = Any User Code
12 = Zone with Delay Transmission Option Enabled is
Breached
01 to 15 = Zones 1 to 15
99 = Any Zone
13 = Arm with User Code 01 to 48 = User Code Numbers 001 to 048
99 = Any User Code
14 = Special Arm 00 = Auto Arming (timed/no movement)
01 = Late to Close (Auto-Arming failed)
02 = No Movement Auto-Arming
03 = Partial Arming (Stay, Force, Instant, Bypass)
04 = One-Touch Arming
05 = Arm with WinLoad Software
07 = Closing Delinquency (Partition 1 only)
99 = Any Sub-Group
15 = Disarm with User Code 01 to 48 = User Code Numbers 001 to 048
99 = Any User Code
16 = Disarm After Alarm w/ User Code 01 to 48 = User Code Numbers 001 to 048
99 = Any User Code
17 = Cancel Alarm with User Code 01 to 48 = User Code Numbers 001 to 048
99 = Any User Code
18 = Special Disarm 00 = Cancel Auto Arm (timed/no movement)
01 = Disarm with WinLoad Software
02 = Disarm after alarm with WinLoad Software
03 = Cancel Alarm with WinLoad Software
99 = Any Sub-Group
19 = Zone Bypassed on Arming 01 to 15 = Zones 1 to 15
99 = Any Zone
20 = Zone in Alarm 01 to 15 = Zones 1 to 15
99 = Any Zone
21 = Fire Alarm 01 to 05 = Zones 1 to 5 (on-board inputs)
99 = Any Zone
22 = Zone Alarm Restore 01 to 15 = Zones 1 to 15
99 = Any Zone
23 = Fire Alarm Restore 01 to 05 = Zones 1 to 5 (on-board inputs)
99 = Any Zone
24 = Special Alarm 00 = Emergency Panic
01 = Auxiliary Panic
02 = Fire Panic
03 = Recent Closing
04 = Auto Zone Shutdown
05 = Duress Alarm
06 = Keypad Lockout
99 = Any Sub-Group
25 = Auto Zone Shutdown 01 to 15 = Zones 1 to 15
99 = Any Zone
26 = Zone Tamper 01 to 15 = Zones 1 to 15
99 = Any Zone
27 = Zone Tamper Restore 01 to 15 = Zones 1 to 15
99 = Any Zone
Event Group # Sub-Group #