Programming Guide

Spectra 1759MG - 12 - Programming Guide
System Options
Bold = Default Setting
* Reassign Keypad Zone 2 and Reassign zones to expansion inputs change the zone numbering to increase the number of
expansion inputs that can be displayed on 10-Zone LED Keypads. Refer to the Zone Recognition Table on page 6 and the
Spectra 1759MG Reference & Installation Manual for details.
Section [126]: General Options
Option
OFF ON
[1]
Confidential Mode N Disabled N Enabled
[2]
To exit Confidential Mode N Enter Access Code N Press a Key
[3]
Confidential Mode timer N 2 minutes N 5 seconds
[4]
PGM1 normal state N Normally Open (N.O.) N Normally Closed (N.C.)
[5]
PGM2 normal state N Normally Open (N.O.) N Normally Closed (N.C.)
[6]
Global PGM normal state N Normally Open (N.O.) N Normally Closed (N.C.)
[7]
Reassign Keypad Zone 2* N Disabled N Enabled
[8]
Reassign zones to expansion inputs* N Disabled N Enabled
Section [127]: General Options
Option
OFF ON
[1]
Partitioning N Disabled N Enabled
[2]
Access code length N 6-digits N 4-digits
[3]
Keypad audible trouble warning N Disabled N Enabled
[4]
Lock System Master Code N Disabled N Enabled
[5]
Battery charge current N 350mA N 700mA
[6]
User Code 048 is a Duress Code N Disabled N Enabled
[7]
Alarm relay follows N Bell Output N Global PGM
[8]
Future use N N/A N N/A
Section [128]: General Options
Option
OFF ON
[1]
Panic 1: keys [1] & [3] N Disabled N Enabled
[2]
Panic 2: keys [4] & [6] N Disabled N Enabled
[3]
Panic 3: keys [7] & [9] N Disabled N Enabled
[4]
Panic 1: silent or audible N Silent N Audible
[5]
Panic 2: silent or audible N Silent N Audible
[6]
Panic 3: silent or fire N Silent N Fire
[7]
Keypad 1 tamper supervision N Disabled N Enabled
[8]
Keypad 2 tamper supervision N Disabled N Enabled
Section [129]: General Options
Option
OFF ON
[1]
PGM2 output activation option N Steady N Pulse (flash)
[2]
PGM2 pulse once every 30 sec. if system armed N Disabled N Enabled
[3]
PGM2 pulse on Arm, twice on Disarm N Disabled N Enabled
[4]
ZX4 & ZX8 zone expansion module supervision N Disabled N Enabled
[5]
Future use N N/A N N/A
[6]
Wireless module low battery supervision N Disabled N Enabled
[7]
4-PGM Output Module supervision (APR3-PGM4) N Disabled N Enabled
[8]
Printer Module supervision (APR3-PRT1) N Disabled N Enabled