Programming Guide
Table Of Contents
- Default Installer Code
- Default System Master Code
- How Do I Enter Programming Mode?
- Decimal and Hexadecimal Programming Table
- Trouble Display
- Data Display Mode (LED Keypads Only)
- Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)
- Zone Programming
- System Timers
- Programmable Outputs
- System Options
- Communication Settings
- Report Codes
- System Settings
- User Code Options
- Reprogram All Modules
- Paradox Memory Key (PMC-3)
- 4-PGM Output Modules V2.0
- Printer Module V2.0
- Voice-assisted Arm/Disarm Bus Module V2.0
- Wireless Features
- Zone Expansion Bus Modules
- User Operation
- Appendix A - Ademco CID Report Code List (Prog.)
- Appendix B - Ademco CID Report Code List (All Codes)
- Bus Module Connections
- Hardware Connections
Spectra 1759MG - 13 - Programming Guide
Bold
= Default Setting
* This option cannot be done using a keyswitch. Force arming is not supported by keyswitches.
Section [130]: Arming/Disarming Options
Option
OFF ON
[1]
One-touch Regular Arming N Disabled N Enabled
[2]
One-touch Stay Arming N Disabled N Enabled
[3]
One-touch Force Arming N Disabled N Enabled
[4]
One-touch bypass programming N Disabled N Enabled
[5]
Restrict arming on battery failure N Disabled N Enabled
[6]
Restrict arming on Tamper failure N Disabled N Enabled
[7]
Bell Squawk on Arm/Disarm with keypad N Disabled N Enabled
[8]
Beep on exit delay N Disabled N Enabled
Section [131]: Arming/Disarming Options
Option
OFF ON
[1]
Report Disarming N Always N Only after alarm
[2]
Regular Arming switches to Force Arming * N Disabled N Enabled
[3]
Bell Squawk on Arm/Disarm with remote control
(must be enabled for UL installations)
N Disabled N Enabled
[4]
No exit delay when Arming with a remote control N Disabled N Enabled
[5]
No exit delay beeps and no Bell Squawk when
Stay Arming
N Disabled N Enabled
[6]
Restrict arming on wireless transmitter
supervision loss
N Disabled N Enabled
[7]
Generate supervision loss if detected on
bypassed wireless zone
N Yes N No
[8]
Future Use N N/A N N/A
Section [132]: Zone Options
Option
OFF ON
[1]&[2]
N see table
N see table
N see table
N see table
[3]
Generate tamper if detected on bypassed zone N Yes N No
[4]
EOL (end-of-line) resistors N No EOL N Use EOL Resistors
[5]
Future use N N/A N N/A
[6]
Report zone restore N On Bell Cut-off N On Zone Closure
[7]&[8]
N see table
N see table
N see table
N see table
Tamper Recognition Options
[1] [2]
OFF OFF Disabled (default)
OFF ON When disarmed: GENERATES TROUBLE ONLY
When armed: Follows Zone Alarm Types
ON OFF When disarmed: GENERATES SILENT ALARM
When armed: Follows Zone Alarm Types
ON ON When disarmed: GENERATES AUDIBLE ALARM
When armed: Follows Zone Alarm Types
Wireless Transmitter Supervision Options
[7] [8]
OFF OFF Disabled (default)
OFF ON When disarmed: GENERATES TROUBLE ONLY
When armed: Follows Zone Alarm Types
ON OFF When disarmed: GENERATES SILENT ALARM
When armed: Follows Zone Alarm Types
ON ON When disarmed: GENERATES AUDIBLE ALARM
When armed: Follows Zone Alarm Types