Programming Guide
Table Of Contents
- Default Installer Code
- Default System Master Code
- How Do I Enter Programming Mode?
- Decimal and Hexadecimal Programming Table
- Trouble Display
- Data Display Mode (LED Keypads Only)
- Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)
- Zone Programming
- System Timers
- Programmable Outputs
- System Options
- Communication Settings
- Report Codes
- System Settings
- User Code Options
- Reprogram All Modules
- Paradox Memory Key (PMC-3)
- 4-PGM Output Modules V2.0
- Printer Module V2.0
- Voice-assisted Arm/Disarm Bus Module V2.0
- Wireless Features
- Zone Expansion Bus Modules
- User Operation
- Appendix A - Ademco CID Report Code List (Prog.)
- Appendix B - Ademco CID Report Code List (All Codes)
- Bus Module Connections
- Hardware Connections
Spectra 1759MG - 20 - Programming Guide
4-PGM Output Modules V2.0
Due to the APR3-PGM4’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or
DGP-NE96 control panel. When connected to the bus, the APR3-PGM4 automatically detects which control panel it is
connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PGM4 can be
connected to each Spectra control panel.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the
APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.
Bold = Default Setting
PGM Programming
Each PGM Deactivation event can be used as another activation event if their respective PGM timer (see sections [501] to
[504]) is programmed with a value other than 000. The APR3-PGM4 uses the same PGM events as the Spectra control
panel, please refer to Programmable Outputs on page 9.
Section # Decimal Value (000-255) Description Default Value
[501] ___/___/___ (000 = follow deactivation event)
PGM1 TIMER 5 sec.
[502] ___/___/___ (000 = follow deactivation event)
PGM2 TIMER 5 sec.
[503] ___/___/___ (000 = follow deactivation event)
PGM3 TIMER 5 sec.
[504] ___/___/___ (000 = follow deactivation event)
PGM4 TIMER 5 sec.
Section # Event Group # Sub-Group # Partition #
[505] PGM1 Activation Event ___/___ ___/___ ___/___
[506] PGM1 Deactivation Event ___/___ ___/___ ___/___
[507] PGM2 Activation Event ___/___ ___/___ ___/___
[508] PGM2 Deactivation Event ___/___ ___/___ ___/___
[509] PGM3 Activation Event ___/___ ___/___ ___/___
[510] PGM3 Deactivation Event ___/___ ___/___ ___/___
[511] PGM4 Activation Event ___/___ ___/___ ___/___
[512] PGM4 Deactivation Event ___/___ ___/___ ___/___
Section [500]: General Options
Option
OFF ON
[1] PGM1 Time Base Selection N Seconds N Minutes
[2] PGM2 Time Base Selection N Seconds N Minutes
[3] PGM3 Time Base Selection N Seconds N Minutes
[4] PGM4 Time Base Selection N Seconds N Minutes
[5] to [8] Future use N N/A N N/A