Programming Guide

Spectra 1759MG - 22 - Programming Guide
Bold = Default Setting
PGM Programming
The PGM Deactivation event can be used as another activation event if the PGM Timer (section [554]) is programmed with a
value other than 000. The APR3-PRT1 module uses the same PGM events as the Spectra control panel, please refer to
Programmable Outputs on page 9.
Section # Decimal Value (000-255) Description Default Value
[554] ___/___/___ seconds (000 = follow deactivation event)
PGM1 TIMER 5s
Section # Event Group # Sub-Group # Partition #
[555] PGM1 Activation Event ___/___ ___/___ ___/___
[556] PGM1 Deactivation Event ___/___ ___/___ ___/___
Clock Programming
For example, to enter the date March 26, 2004 you would enter 2004 (year), 03 (month), and 26 (day).
Section # Value
[557] Year ___/___/___/___ Month ___/___ Day ___/___
Section [553]: Serial and Parallel Port Setup Options
Option
OFF ON
[1]
Serial port N Disabled N Enabled
[2]&[3]
N see table
N see table
N see table
N see table
[4]
Parallel port N Disabled N Enabled
[5]
Off-line status ignored (parallel port only) N Disabled N Enabled
[6]
Paper empty status ignored (parallel port only) N Disabled N Enabled
[7]
Printer fault status ignored (parallel port only) N Disabled N Enabled
[8]
Printer busy status ignored (parallel port only) N Disabled N Enabled
Baud Rate Settings
[2] [3] APR-PRT1 APR3-PRT1
OFF OFF 1200 baud (default) 2400 baud (default)
ON OFF 2400 baud 9600 baud
OFF ON 9600 baud 19200 baud
ON ON 19200 baud 57600 baud